© Voltex Electrical 2016. All Rights Reserved.
®
INSTALLATION:
Remove all packaging from the appliance before commencing installation. Ensure
the circuit has been isolated from the mains supply BEFORE commencing work.
1.
Locate in accordance with the requirements of the wiring rules relating to
damp situations. National and local council regulations concerning the
discharge of air must also be fulfilled.
2.
For installation where external venting is required or is your choice,
select a suitable location in the exterior side wall or under the eave to vent
out the exhausted air/steam and cut out a
Φ
105
m
m hole. NOTE: Make
sure
the ducting will reach from the centre of installation of the appliance
to
the external vent.
3.
Put one end of the 100mm ventiduct through the hole and secure the duct
to a suitable outlet grill and if necessary seal the join with duct tape and
seal space around the hole using a suitable sealant where necessary. Fix
the outlet grill to the wall/eave.
4.
Choose a suitable mounting location in the ceiling. Note it should not be
where it may come into contact with water for example above a shower or
bath. Centre of room is ideal. If not, at least 250mm from a wall.
5.
Use the template card provided as a hole cutting template
6.
Do not install above or adjacent to a cooking appliance.
7.
The fan is intended to be mounted at high level and must be installed so
that the blades are more than 2.1m above the floor.
8.
CAUTION:
Ensure that the intended hole will have suitable room to locate
the unit and that it will not interfere with joists or the ceiling structure.
Joists, beams and rafters shall not be cut or notched to install the
appliance.
9.
There must be adequate clearances. Make sure a minimum of 250mm is
maintained between the appliance and any wall. There should be a
minimum of 300mm height clearance in the ceiling for objects above
the
housing. A minimum of 30mm clearance is required around the hole
for the fan, the vertical sides of the appliance and any adjoining parts of
the roof
structure, such as joists or insulation batts. Refer also Figure 1
.
Dimensions below.
10.
Use the template card provided as a hole cutting template to mark out the
intended hole for mounting the appliance (it may be safer to mark the
position from above the ceiling where obstructions are clearly visible,
rather than from inside the room).
(V
EFLED
-200:
Φ
240mm or V
EFLED
-250:
Φ
310mm).