R
EMOTE
O
PERATION
Page 52
© Voltech 2010
Power Analyzer User Manual
Status Byte Register (STB)
Read by “*STB?”.
ESB
DAS
Bit 5 - ESB
Summary bit to show standard event status.
Bit 0 - DAS
Summary bit to show display data available.
Display Data Status Register (DSR)
Read by “:DSR?” or in summary by *STB? DAS bit. On power-up DSR is
initialized to zero. When read using the “:DSR?” command the register is
cleared.
IEC_Flick
IFS
IEC_Flick
Bin
IEC_FLU OVV OVA NDV
DVL
Bit 7
– IEC_FlickIFS
Set to indicate availability of new IFS data in IEC Flicker
mode. Cleared when read.
Bit 6
– IEC_FlickBin
Set to indicate availability of new IEC Flicker Bin data in
IEC Flicker mode. Cleared when read.
Bit 5
– IEC_FLU
Set to indicate availability of new IEC Fluctuating
Harmonics data in IEC Fluctuating Harmonics mode.
Cleared when read.
Bit 4 - OVV
Set to indicate there is a voltage range overload. Automatically
cleared when range overload clears.
Bit 3 - OVA
Set to indicate there is a current range overload. Automatically
cleared when range overload clears.
Bit 1 - NDV
Set to indicate that new data has become available since the last
:DSR? command. Cleared when read.
Bit 0 - DVL