DC-DC Battery Charger Mode
Float (GEL/ AGM)
13.2V
Float (WET)
13.5V
Float (Calcium-Calcium)
13.8V
Absorption (GEL/ AGM)
14.1V
Absorption (WET)
14.4V
Absorption (Calcium-Calcium)
15.5V
With Optional Remote Control Module BBR-3100
User Defined Float Voltage Range
12.6V ~ 14.0V
User Defined Absorption Voltage Range
13.0V ~ 15.5V
User Defined Absorption Time Range
1 ~ 6hours
DC Voltage Reducer Mode
Regulated Output Voltage
13.8V
Battery Equalizer Mode: Output V =
½
Input V (11-15V)
Output Voltage
½
Input Voltage
±
3%
Voltage Regulation:
Load
200mV
Line
80mV
Ripple & Noise
35mVrms
DC Input Current
No Load Input Current (Standby)
170mA
Full Load Input Current (at output 13.8V / 40A)
26.5A
Input Current Level when Output Short Circuit
2.5A
Protections
Input Under Voltage (LVD Low Voltage Disconnect), (Auto reset)
(22V) (24V)
Input Over Voltage (Auto Reset)
32V
Output Over Voltage (Manual Reset)
17.5V
Output Over Current / Short Circuit (Manual reset)
41A
Battery Over Temp. with remote temp. sensor (Auto Reset)
60°C
Unit Over Temperature Protection
Yes
Reverse Polarity (Output)
30A x 2 Fuses
Other
Approval
CE EMC EN55014
Dimensions (L x W x H) mm
243 x 156 x 61
Weight
Approx. 2.4kg
Supplied Accessories:
A. one set of mounting bracket & taper screws
B. hardwire input cable 1600mm AWG#22
C. one single red wire (for ignition control) 1500mm AWG#22
Optional Accessories:
A. Remote Display Module BBR-3100
B. Remote Temperature Sensor for battery model ATS-5120