55
Direct current
Range Accuracy
Resolution:
VC265
VC280
400 µA
±(1.3% + 3)
±(1.3% + 3)
0.1 µA
4000 µA
0.001 mA
40 mA
±(1.5% + 5)
±(1.5% + 5)
0.01 mA
400 mA
0.1 mA
4 A
±(1.8% + 8)
±(4.6% + 39)
0.001 A
10 A
- - - -
0.01 A
40 A
- - - -
±(4.6% + 7)
0.01 A
Overload protection: Fuses;
Overload protection;
600 V; measuring time limit
mA-PTC-Fuse 600 V;
>5 A: max. 10 s with break
Measuring time: unlimited
of 15 min
Alternating current
Range Accuracy
Resolution:
VC265
VC280
400 µA
±(1,6% + 3)
±(1.6% + 3)
0.1 µA
4000 µA
0.001 mA
40 mA
±(2,0% + 5)
±(2,0% + 5)
0.01 mA
400 mA
0.1 mA
4 A
±(2,0% + 8)
±(4.6% + 39)
0.001 A
10 A
- - - -
0.01 A
40 A
- - - -
±(4.6% + 7)
0.01 A
Frequency range 45 Hz - 1 kHz; Frequency range
TrueRMS; Crest factor max. 3.0
40 Hz - 400Hz; Crest factor
Overload protection: Fuses600V; max. 3.0 Overload
Measuring time limited >5 A:
protection; mA- PPTC
max. 10 s with break of 15 min
Fuse 600 V