43
Alternating voltage (A DC)
Range
Accuracy (at 50/60 Hz)
Resolution
200 V
±(1.5% + 12)
0.1 V
600 V
1 V
Frequency range 45 – 450 Hz; Overload protection 600 V; Impedance: >1 MΩ
Direct current
Range
Accuracy
Resolution
2000 µA
±(1.5% + 3)
1 µA
20 mA
0.01 mA
200 mA
0.1 mA
10 A
±(2.5% + 2)
0.01 A
Overload protection 600 V; high-performance ceramic fuses:
Resistance
Range
Accuracy
Resolution
200.0 Ω
±(1.2% + 4)
0.1 Ω
2000 Ω
1 Ω
20.00 kΩ
0.01 kΩ
200.0 kΩ
0.1 kΩ
2000 kΩ
±(1.5% + 2)
1 kΩ
Overload protection 250 V; max. 15 s.
Battery test
Range
Accuracy
Resolution
1.5 V
±(1.5% + 3)
0.001 V
9 V
0.01 V
Load current:
1.5 V-range: 100 mA
9 V-range: 6 mA