b) Connected devices
• Also observe the safety and operating instructions of any other devices which are
connected to the product.
c) Product
• The measuring adapter and the plugs may not be disassembled.
•
The voltage and current range specified should not be exceeded.
• The measuring adapter may only be used for current and voltage measurement.
• The user is not allowed to put other items than suitable safety measuring cables
in the sockets
• Current measurement on the measurement sockets is not possible (an attempt
would short-circuit the device)!
• The user may not short-circuit the contacts of the measuring adapter.
Operation
The current is measured with commercial AC current clamps on the insulated meas-
uring chambers and the voltage is measured with voltage measuring devices on the
measuring so-ckets.
Both types of measurement can be carried out at the same time. Only use the meas-
uring adapter for the duration of the measurement. A permanent retention in the
mains cable circuit is not permitted.
CAT III
Overvoltage category III for measurements on electric and electronic devices con-
nected to the mains supply with a mains plug. This category also covers all lower
categories (e.g. CAT I for measuring signal and control voltages).
Care and cleaning
• Apart from the occasional cleaning the adapter is maintenance free.
• Disconnect the product from the mains before each cleaning.
• Do not use any aggressive cleaning agents, rubbing alcohol or other chemical solutions as
they can cause damage to the housing and malfunctioning.
•
Clean the product with a dry, fibre-free cloth.
Disposal
Electronic devices are recyclable waste and must not be disposed of in the house-
hold waste. At the end of its service life, dispose of the product in accordance with
applicable regulatory guidelines.
You thus fulfill your statutory obligations and contribute to the protection of the envi
-
ronment.
Technical data
Nominal voltage ............................ max. 250 V/AC, 50/60 Hz
Nominal current ............................ max. 16 A
Protection type .............................. IP40
Operating temperature ................. 0 to +40 °C
Operating humidity ....................... max. 80 % up to 31°C
decreasing linearly to 50 % at 40°C
Storage temperature ..................... -20 to +60 °C
Storage humidity ........................... <80 % RH (non condensing)
Altitude .......................................... max. 2100 m
Overvoltage category ................... CAT III 300 V
Dimensions (L x W x H) ................ 162 x 68.5 x 58 mm
Weight .......................................... approx. 206 g
Important Information
VC-523 Measuring adapter
Item No. 2435657
Intended use
The product provides a safe and easy way to measure the AC current of plug-in appliances
and other electrical devices.
The measuring adapter is inserted between the electrical consumer and the socket.
The measuring adapter may only be used in the range of the overvoltage category CAT III in AC
voltage networks (nominal voltage max. 250 V/AC, nominal current max. 16 A).
Only use the measuring adapter for the duration of the measurement. A permanent retention in
the mains cable circuit is not permitted.
The measuring operation is only permitted in dry surroundings.
For safety and approval purposes, you must not rebuild and/or modify this product. If you use
the product for purposes other than those described above, the product may be damaged. In
addition, improper use can result in short circuits, fires, electric shocks or other hazards. Read
the instructions carefully and store them in a safe place. Make this product available to third
parties only together with its operating instructions.
This product complies with the statutory national and European requirements. All company
names and product names are trademarks of their respective owners. All rights reserved.
Delivery content
• Measuring adapter
• Operating instructions
Up-to-date operating instructions
Download the latest operating instructions at www.conrad.com/downloads or
scan the QR code shown. Follow the instructions on the website.
Explanation of symbols
The symbol with the lightning in the triangle is used if there is a risk to your health,
e.g. due to an electric shock.
The symbol with the exclamation mark in the triangle is used to indicate important
information in these operating instructions. Always read this information carefully.
Safety instructions
Read this document and the accompanying operating instructions carefully
and especially observe the safety information. If you do not follow the safety
instructions and information on proper handling, we assume no liability for
any resulting personal injury or damage to property. Such cases will invalidate
the warranty/guarantee.
a) General information
• The device is not a toy. Keep it out of the reach of children and pets.
• Do not leave packaging material lying around carelessly. This may become dan-
gerous playing material for children.
• Protect the appliance from extreme temperatures, direct sunlight, strong jolts, high
humidity, moisture, flammable gases, steam and solvents.
• Do not place the product under any mechanical stress.
• If it is no longer possible to operate the product safely, take it out of operation and
protect it from any accidental use. Safe operation can no longer be guaranteed
if the product:
- is visibly damaged,
- is no longer working properly,
- has been stored for extended periods in poor ambient conditions or
- has been subjected to any serious transport-related stresses.
• Please handle the product carefully. Jolts, impacts or a fall even from a low height
can damage the product.
• Consult an expert when in doubt about the operation, safety or connection of the
appliance.
•
Maintenance, modifications and repairs must only be completed by a technician
or an authorised repair centre.
• If you have questions which remain unanswered by these operating instructions,
contact our technical support service or other technical personnel.
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com). All rights in-
cluding translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data
processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This publication
represent the technical status at the time of printing.
Copyright 2021 by Conrad Electronic SE.
*2435657_v2_1121_02_dh_ss_en_(measuring adapter)