Technical Data
Transmitter LSG-10B
Output signal
125 kHz
External voltage recognition
12 – 400 V AC/DC
Frequency range
0 – 60 Hz
Display
LC display
Operating voltage
9V block battery
Power input
max. 18 mA
Auto-power off
approx. 1 hour
Ceramics fuse
FF 500 mA H 1000 V (6.3 x 32 mm)
Working conditions
0 - 40°C (<80%rF)
Operating altitude
max. 2,000 m
Storage temperature
-20°C to +60°C (<80%rF)
Weight
approx. 130 g
Dimensions (LxWxH)
130 x 69 x 32 (mm)
Over-voltage category
CAT III 300 V, Impurity level 2
Receiver LSG-10
Detection depth
0 – 2 m (One-pole measurement)
0 – 0.5 m (Two-pole measurement)
0 – 0.4 m (NCV mode)
Display
LC display
Operating voltage
9V block battery
Power input
max. 40 mA
Auto-power off
approx. 10 minutes
Working conditions
0 - 40°C (<80%rF)
Operating altitude
max. 2,000 m
Storage temperature
-20°C to +60°C (<80%rF)
Weight
approx. 180 g
Dimensions (LxWxH)
192 x 61 x 37 (mm)