Finding Heating Tubes in the Floor
For the best search results, the heating pipes
should be disconnected from the earth connection.
Connect the transmitter to the heater’s metal pipe
and an earth connection.
☞
Suitable earth connections are any
power outlet protective conductors.
Trace the pipe’s course with the receiver.
Localising a Complete Electronic Installation
Switch off the fuses and power down
the whole system. This measurement
requires manipulating the main electri-
cal distribution system and must only
be performed by an electrician.
With the cable detector, all present outlets and
cables can be determined and checked for contact.
Remove the main distribution bridge between the
protective conductor “PE” and the neutral conduc-
tor “N”.
Connect the transmitter to the distribution main of
“N” and “PE”.
The neutral conductor can be traced through the
complete system with the receiver.