 •   This instrument left the factory in perfect condition in terms of safety engineering. 

 

 •   We kindly request the user to observe the safety instructions and warnings contained in the 

enclosed operating instructions so this condition is maintained and to ensure safe operation. 

 

•   The unauthorised conversion and/or modification of the unit is not permitted for safety and 

approval reasons (CE).

 

•   Consult a professional if you are unsure how to operate the equipment or how to connect it 

safely.

 

•   The device must not be opened. Live parts may be exposed, when covers are opened or 

parts are removed - unless you can do this by hand. Capacitors inside the device may still be 

charged, even if the device has been disconnected from all power sources.

 

•   Never touch the device with wet or moist hands. There is danger of a life-threatening electric 

shock.

 

•   Power supply units and connected loads must not be operated unattended.

 

•   Only use fuses of the rated type and current. It is absolutely prohibited to use repaired fuses.

 

•   Do not use non-insulated metallic leads.

 

•   Keep the unit out of the reach of children. It is not a toy.

 

•   In commercial institutions, the accident prevention regulations of the Employer’s Liability 

Insurance Association for Electrical Systems and Operating Facilities are to be observed.

 

•   In schools and training centres as well as at hobby and DIY workshops, the use of power 

packs must be supervised by adequately trained personnel in a responsible manner.

 

•   The device will warm up during operation. Ensure sufficient ventilation of the device. Do not 

cover or seal the ventilation apertures of the device. Do not touch the cooling element on the 

rear during operation. Risk of burns!

 

•   Due to the variety of furniture protection products the base of the device may chemically react 

with the surface. Place the device on a hard-wearing, smooth and flat surface.

 

•   If you have reason to assume that safe operation is no longer possible, disconnect the device 

immediately and secure it against inadvertent operation. 

 

•  Safe operation can no longer be assumed if:

 

  -  the device is visibly damaged,

 

  -  the device does not function any more and

 

  -  the device was stored under unfavourable conditions for a long period of time or

 

  -  it has been subjected to considerable stress during transportation.

 

•   You should also heed the safety instructions in each chapter of these operating instructions 

as well as in the operating instructions for connected devices.

 

•   Never switch the device on immediately after having taken it from a cold to a warm environ-

ment. Condensation that forms might destroy your device under unfavourable conditions. 

Allow the device to reach room temperature before switching it on.

 

•   Do not place any vessels with liquids on the device.

 

•   The power supply unit is not approved for use on humans or animals.

CONTROL ELEMENTS

(1)  Power switch for switching the device on (I =ON / 0=OFF)
(2)  Adjustment controller for output voltage, COARSE = coarse, FINE = fine
(3)  Indicator for active output (OUTPUT)
(4)  Button to preset the current limit (C-Limit)
(5)  Display for output voltage “V”
(6)   Carrying handle
(7)  Display for current “A” indicator
(8)  O.T. warning indicates over temperature cut-off
(9)  C.C. indicating active current limit (constant current operation)
(10)  C.V. indicating constant voltage mode (normal mode)
(11)  Adjustment controller for max. output current “A”
(12)  4 mm safety socket DC output  “positive terminal” (+)
(13)  4 mm safety socket “earth potential” (earth)
(14)  4 mm safety socket DC output  “negative terminal” (-)
(15)  Cooling element (rear); heats up during operation!
(16)  Earthed non-heating connection (rear), IEC 320 C14
(17)  Mains fuse holder (rear)

G

 OPERATING INSTRUCTIONS

LABORATORY POWER SUPPLY UNIT

ITEM NO. 1380494 LPS 1305
ITEM NO. 1380495 LPS 1153

INTENDED USE

The laboratory power supply unit serves as a potential-free DC voltage source to operate low-voltage 

consumers. The devices are connected via 4 mm safety sockets at the front.

   Sufficiently dimensioned connecting cables must be used. A conductor cross-section 

that is too small can result in overheating and fire.

The output data of the laboratory measuring devices is as follows:

Type

Output voltage

Output current

LPS1305

0 - 30 V/DC

0 - 5 A

LPS1153

0 - 15 V/DC

0 - 3 A

The settings for current and voltage are made via stepless control knobs. Voltage settings are made via 

coarse and fine controls in order to allow the fast and precise setting of values. The values are displayed 

on two high-contrast LED displays. The current limit for constant current operation can be preset without a 

jumper.
The device is overload and short-circuit-proof and contains a safety temperature cut-off.
Product design complies with the protection class 1. Only supply the product with a voltage from an 

earthed standard mains socket connected to the public power grid. The mains socket must be near the 

device and easily accessible, or an emergency stop device must be present.
Do not connect the outputs of several power supply units in parallel. This could result in  dangerous contact 

voltages developing or the device may  be destroyed.
Operation in hazardous areas (Ex) or rooms with high humidity levels or under adverse ambient conditions 

is not permitted. Adverse environmental conditions are:
-  Dampness or excessive humidity
-  Dust and combustible gases, vapours or solvents
-  Thunderstorms or similar weather conditions such as strong electrostatic fields, etc.
Any use other than that described above can lead to damage to the product and may involve additional 

risks such as short circuits, fire, electric shock etc. No part of the product may be modified or converted! 
The safety instructions are to be observed without fail!

PACKAGE CONTENTS

•  Laboratory power supply unit
•  Operating instructions

  Up-to-date Operating Instructions:    

 

1.   Open produktinfo.conrad.com in a browser or scan the displayed QR code.

 

2.   Select document type and language and enter the item number into 

the search field. After submitting the query you can download displayed 

records.

SYMBOLS EXPLAINED

  

An exclamation mark in a triangle indicates important information contained in these operating 

instructions that must be observed by all means.

   The product is CE compliant and meets the requirements of the current European and national 

guidelines.

   Terminal for the internal protective earth conductor; this screw/contact must not be unscrewed.

  Earth potential

  Only to be used in dry indoor areas. 

SAFETY INSTRUCTIONS

   Please read all the instructions before using this device; they contain important informa-

tion on its correct operation.

 

 Damages caused by failure to follow these operating instructions will void the warranty/

guarantee! We do not assume any liability for any resulting damage!

 

 We do not assume any liability for personal injuries and material damages caused by the 

improper use or non-compliance with the safety instructions! In such cases, the warranty 

will be null and void.

VERSION 12/15

Summary of Contents for LPS1305

Page 1: ...chse Pluspol 13 4 mm Sicherheitsbuchse Erdungspotential Masse 14 DC Ausgang 4 mm Sicherheitsbuchse Minuspol 15 K hlk rper Ger ter ckseite wird bei Betrieb hei 16 Schutzkontakt Kaltger teanschluss Ger...

Page 2: ...farbige 4 mm Sicherheitsbuchsen 12 und 14 Die K hlung des Netzger tes erfolgt aktiv durch einen integrierten permanenten Ger tel fter auf eine ausreichende Luftzirkulation bzw Seitenabstand ist deshal...

Page 3: ...ty socket DC output positive terminal 13 4 mm safety socket earth potential earth 14 4 mm safety socket DC output negative terminal 15 Cooling element rear heats up during operation 16 Earthed non hea...

Page 4: ...A is shown in the display 5 and 7 A secondary side DC connection is possible via two coloured 4 mm safety sockets 12 and 14 The power supply unit is actively cooled by the device s permanently integra...

Page 5: ...de fonctionnement en tension constante fonctionnement normal 11 Bouton pour r gler le courant de sortie max A 12 Sortie CC prise de s curit de 4 mm p le positif 13 Prise de s curit de 4 mm potentiel...

Page 6: ...t avec des connecteurs standard 4 mm La prise de potentiel de terre vert jaune est reli e directement au conducteur de protection Allumez l appareil L indicateur du courant A 7 affiche le courant cons...

Page 7: ...assa 14 DC uitgang 4 mm veiligheidsbus Minuspool 15 Koelelement achterkant toestel wordt heet tijdens gebruik 16 Geaarde koelapparaataansluiting achterkant apparaat IEC 320 C14 17 Veiligheidshouder vo...

Page 8: ...De aansluiting werkt met standaard 4 mm stekkers De groen gele aardpotentiaalbus is direct met de aardleiding verbonden Schakel de verbruiker in De stroomindicatie A 7 geeft de stroom aan die de aange...

Reviews: