Safety information

Read the operating instructions carefully and especially observe the safety 

information. If you do not follow the safety information and information on 

proper handling in these operating instructions, we will assume no liability for 

any resulting personal injury or damage to property. Such cases will invalidate 

the warranty/guarantee.

a) General information

•  The device is not a toy. Keep it out of the reach of children and pets.
•  Do not leave packaging material lying around carelessly. It may become a dange-

rous plaything for children.

•  Protect the product from extreme temperatures, direct sunlight, strong vibrations, 

high humidity, moisture, combustible gases, vapours and solvents.

•  Do not place the product under any mechanical stress.
•  If it is no longer possible to operate the product safely, stop using it and prevent 

unauthorised use. Safe operation can no longer be guaranteed if the product:

 - is visibly damaged, 
 - is no longer working properly, 
 - has been stored for extended periods in adverse ambient conditions or 
 - has been subjected to any serious transport-related stress.

•  Handle the product with care. Jolts, impacts or a fall even from a low height may 

damage the product.

•  Consult a technician if you are not sure how to use or connect the product, or if 

you have concerns about safety.

• 

Maintenance, modifications and repairs may only be carried out by a technician or 

a specialist repair centre.

•  If you have questions which remain unanswered by these operating instructions, 

contact our technical support service or other technical personnel.

b) 

Connected devices

•  Always observe the safety information and operating instructions of any other de-

vices which are connected to the product.

c) Electrical safety

•  The mains socket must be located near to the device and be easily accessible.
•  The product must only be powered by a standard mains socket connected to the 

public grid. Before plugging the product in, check that the voltage indicated on the 

product corresponds to the voltage of your electricity supplier.

•  Never unplug the mains plug by pulling on the cable. Always use the grips on 

the plug.

•  Unplug the mains plug from the mains socket if you do not plan to use the product 

for an extended period of time.

•  For safety reasons, disconnect the mains plug from the mains socket during thun-

derstorms.

•  Ensure that the mains cable is not squeezed, bent, damaged by sharp edges or 

subjected to mechanical stress. Avoid excess thermal stress on the mains cable 

due to excessive heat or cold. Do not modify the mains cable. Failure to adhere 

to these instructions may lead to damage of the mains cable. A damaged mains 

cable can cause a fatal electric shock.

•  Do not touch the mains cable if there are any signs of damage. Power down the 

respective mains socket (e.g. via the respective circuit breaker), and then carefully 

unplug the mains plug from the mains socket. Never use the product if the mains 

cable is damaged.

•  Damaged mains cables must be replaced by the manufacturer, an authorised re-

pair centre or a qualified electrician.

•  Never connect or disconnect power plugs when your hands are wet.
•  Only use the power cable and power adapter supplied with the product and certi-

fied for use in your country.

•  Never switch the device on immediately after moving it from a cold to a warm 

environment. The condensation generated may destroy the product. Leave the 

device switched off and allow it to reach room temperature.

d) Persons and product

•  Do not disassemble the product. This may cause a fatal electric shock!
•  Store the oscilloscope in a well-ventilated place. Make sure that the instrument is 

properly ventilated. Refer to the operating instructions for details.

•  Do not work in areas where there is a danger of explosion.
•  Keep all surfaces of the product clean and dry.
•  Do not use the device in rooms or unfavourable ambient conditions in which there 

are or could be combustible gases, vapours or dust.

e) Measuring mode

•  Ensure that the probes are connected in the correct polarity. Do not connect the 

negative measuring lead to the positive pole.

•  Connect the measuring cables to the oscilloscope before connecting the probes 

to the signal measuring circuit. After finishing the measurements, disconnect the 

measurement probes from the measuring circuit before before disconnecting them 

from the oscilloscope.

 Safety information

Digital hand oscilloscope DSO-5104H
Digital hand oscilloscope DSO-5072H

Item no. 2266525
Item no. 2267610

Intended use

This product is designed to provide visual representation of electrical quantities and signals. 

Two (for item no. 2267610) or four (for item no. 2266525) input channels are available for taking 

measurements. The measuring leads are connected to the oscilloscope via BNC sockets. Mea-

surements are displayed on a 20.32 cm (8”) colour LCD touchscreen with 800 x 600 pixels. The 

measured signals can be displayed on the LCD display or on a PC via USB cable.
The maximum input quantities indicated on the device must never be exceeded.
These safety instructions are primarily intended to explain safety measures in order to make 

working with the device as safe as possible. The individual device functions are explained in 

more detail in the help menu of the oscilloscope or in the operating instructions.
Always observe the safety instructions and the help menus!
This product is intended for indoor use only. Do not use it outdoors. Contact with moisture 

(e.g. in a bathroom) must be avoided under all circumstances.
For safety and approval purposes, do not rebuild and/or modify this product. Using the product 

for purposes other than those described above may damage the product. In addition, improper 

use can cause hazards such as a short circuit, fire or electric shock. Read the operating instruc

-

tions carefully and store them in a safe place. Only make this product available to third parties 

together with its operating instructions.
This product complies with statutory, national and European regulations. All company and pro-

duct names contained herein are trademarks of their respective owners. All rights reserved.

Package contents

a) Item no. 2266525

•  Digital oscilloscope
•  Power cable
•  Power adapter
•  USB cable
•  4x Measurement probes
•  2x Adjustable measurement probes

•  BNC-SAM
•  Stand with holder
•  Software and manual on CD
•  Quick start guide
•  Information sheet with safety notes

b) Item no. 2267610

•  Digital oscilloscope
•  Power cable
•  Power adapter
•  USB cable
•  2x Measurement probes
•  Adjustable measurement probes
•  BNC-SAM

•  Test leads (red/black)
•  Ext. power module
•  Stand with holder
•  Software and manual on CD
•  Quick start guide
•  Information sheet with safety notes 

Up-to-date operating instructions  

Download the up-to-date operating instructions at www.conrad.com/down-

loads or scan the QR code shown. Follow the instructions on the website.

Description of symbols

  The symbol with the lightning in a triangle indicates that there is a risk to your health, 

e.g. due to an electric shock.

  The symbol with an exclamation mark in a triangle points to important information in 

these operating instructions which must be observed.

  The arrow symbol indicates special information and tips on how to use the product.

  Test ground

  All metal parts that could carry a voltage in the event of a fault during operation or 

maintenance must be connected to the protective earth conductor.

  Housing ground

Summary of Contents for DSO-5104H

Page 1: ...sorgung nur das mit dem Produkt gelieferte und für die Verwendung in Ihrem Land zertifizierte Netzkabel und Netzteil Schalten Sie das Gerät niemals gleich dann ein wenn dieses von einem kalten in einen warmen Raum gebracht wird Das dabei entstandene Kondenswasser kann unter Umständen Ihr Gerät zerstören Lassen Sie das Gerät uneingeschaltet auf Zimmertemperatur kommen d Personen und Produkt Zerlege...

Page 2: ...ile wenn darin höhere Spannungen als 30 V AC rms oder 30 V DC 42 V Spitze oder Stromkrei se in denen mehr als 4800 VAanliegen können Lebensgefahr Bereits bei diesen Spannungen können Sie bei Berührung elektrischer Leiter einen lebensgefährli chen elektrischen Schlag erhalten Die Kanäle des Oszilloskops sind nicht elektrisch isoliert Alle Kanäle haben wäh rend der Messungen eine gemeinsame Erdung U...

Page 3: ...ventilated place Make sure that the instrument is properly ventilated Refer to the operating instructions for details Do not work in areas where there is a danger of explosion Keep all surfaces of the product clean and dry Do not use the device in rooms or unfavourable ambient conditions in which there are or could be combustible gases vapours or dust e Measuring mode Ensure that the probes are co...

Page 4: ...ground during measurements To prevent short circuits the grounds must not be connected to 2 different non insulated voltage levels Do not measure an AC signal when the oscilloscope is powered by AC I or when the oscilloscope is connected to an AC powered computer while on battery power II I Signal Erde Prüfspitzen Oszilloskop Netzteil Steckdose Probes Signal Earth Oscilloscope Power adapter Socket...

Page 5: ...l vient d être transporté d une pièce froide vers un local chaud L eau de condensation qui en résulte pourrait dans certaines circonstances de détruire l appareil Laissez l appareil atteindre la tem pérature ambiante avant de l allumer d Personnes et produit Ne démantelez pas le produit Vous vous exposez à un danger de mort par élec trocution Utilisez l oscilloscope dans un endroit bien ventilé As...

Page 6: ...0 V CC crête à 42 V ou les circuits dans lesquels plus de 4800 VA peuvent être appliqués Danger de mort En cas de contact avec des pièces électriques munies de telles tensions vous courez un risque d électrocution mortelle Les canaux de l oscilloscope ne sont pas isolés électriquement Tous les canaux ont une mise à la terre commune pendant les mesures Pour éviter les courts circuits ne connectez p...

Page 7: ...naar een war me kamer is verplaatst De condens die hierbij wordt gevormd kan het apparaat onder bepaalde omstandigheden onherstelbaar beschadigen Laat het apparaat eerst op kamertemperatuur komen voordat u het inschakelt d Personen en product Haal het product niet uit elkaar Er bestaat gevaar voor een levensgevaarlijke elektrische schok Gebruik de oscilloscoop op een goed geventileerde plek Zorg e...

Page 8: ...an 4800 VAaanwezig kunnen zijn Levensgevaar Bij deze spannin gen kunt u in geval van contact met een elektrische kabel een levensgevaarlijke elektrische schok krijgen De kanalen van de oscilloscoop zijn niet elektrisch geïsoleerd Alle kanalen heb ben tijdens de metingen een gemeenschappelijke aarding Om kortsluiting te voorkomen mogen de aardingen niet met 2 verschillende niet geïsoleerde span nin...