background image

•  Do not use this product in rooms or under adverse ambient conditions where 

combustible gases, vapours or dust are or may be present! There is a risk of 

explosion!

•  The power adapter complies with protection class II.
•  In commercial institutions, the accident prevention regulations of the Employer’s 

Liability Insurance Association for Electrical Systems and Operating Materials are 

to be observed.

•  Carbon dioxide (CO

2

) is a transparent and odourless gas. Pay attention to your 

own safety during all measurements. To protect the life of humans and animals, 

this device must not be used in areas where high concentrations of carbon dioxide 

are used industrially.

•  Consult an expert when in doubt about the operation, safety or connection of the 

appliance.

• 

Maintenance, modifications and repairs must only be completed by a technician 

or an authorised repair centre.

•  If you have questions which remain unanswered by these operating instructions, 

contact our technical support service or other technical personnel.

Operating Elements

1

9

8

7

6

5

4

3

2

10

11

1  Indication of the CO

2

-concentration in ppm

2  Indication of the room temperature in °C
3  Green LED (CO

2

-concentration <800 ppm)

4  “MUTE”-key for muting the warning signal
5  Red LED (CO

2

-concentration >1500 ppm)

6  Yellow LED (CO

2

-concentration 800 - 1500 ppm)

7  Indication of the humidity in the room
8  Symbol for warning signal on/off
9  Socket for the connection of the power supply
10 Suspension eye for mounting the product on a wall
11 Fold-out base

Installation/Setup

Place the ambient air indicator, such that sufficient ambient air can flow through it. The air flow 

for the measurement enters the device at the back. Avoid narrow spaces, for example between 

books etc. in order to prevent any effects on the measured results. Choose a place where a 

mains socket is available close by.
The product can be suspended easily on two screws, nails or wall hooks using the suspension 

eyes 

(10)

 on the backside.

Alternatively, it is also possible to fold out a foot 

(11)

.

Get Started

Connect the power supply unit to the socket 

(9)

 on the side of the product using the enclosed 

USB cable and plug it into a mains socket.

  Alternatively, the ambient air display can also be powered via a USB port. This must 

be a so-called high-power USB port that can supply a current of at least 500 mA.

All display segments appear and the ambient air indicator emits a brief alarm sound.
For a few seconds, the display will only show lines for the CO

2

-concentration 

(1)

, the room 

temperature 

(2)

 and the indoor humidity 

(7)

.

Then, the room temperature and the indoor humidity are displayed.
Due to the fact that the sensor needs a short warm-up, it should take another 2 minutes until 

the first measurement of CO

2

-concentration appears on the display.

Operation

a) Indication of the CO

2

-concentration, the room temperature and the indoor 

humidity.

The ambient air indicator is in automatic measuring mode after the warm-up phase (approx. 

2 minutes). The CO

2

-concentration is shown on the upper display 

(1)

 in ppm, the room 

temperature (°C) in the display at the left side on the bottom 

(2)

 and the relative humidity in the 

room in the display at the right side on the bottom 

(7)

.

 Operating Instructions

AMBIENT AIR INDICATOR CO-60 

Item No. 101300

Intended Use

The ambient air indicator “CO-60” is a stationary measurement unit for recording the carbon 

dioxide concentration (CO

2

) in the ambient air with an exact and long-term stable measuring 

method of the NDIR (Non- Dispersive-Infrared-Spectroscopy).
The meter is intended for monitoring the carbon dioxide level in the room air to take appropriate 

measures for ventilation in advance. An increased CO

2

 level leads to fatigue, lack of 

concentration and loss of efficiency and performance.
The quality level is displayed by means of a traffic light indicator (green/yellow/red). The air 

temperature and humidity are measured at the same time. All three values are indicated on the 

display at the same time.
Operation is enabled by the enclosed wall plug transformer.
It is intended for indoor use only. Do not use it outdoors. Contact with moisture, e.g. in 

bathrooms, must be avoided under all circumstances.
For safety and approval purposes, you must not rebuild and/or modify this product. If you use 

the product for purposes other than those described above, the product may be damaged. In 

addition, improper use can result in short circuits, fires, electric shocks or other hazards. Read 

the instructions carefully and store them in a safe place. Make this product available to third 

parties only together with its operating instructions.
This product complies with the statutory national and European requirements. All company 

names and product names are trademarks of their respective owners. All rights reserved.

Delivery Content

•  Ambient air indicator
•  Wall plug transformer

•  USB cable
•  Operating instructions

Up-to-date Operating Instructions           

Download the latest operating instructions at www.conrad.com/downloads or 

scan the QR code shown. Follow the instructions on the website.

Explanation of Symbols

  The symbol with the lightning in the triangle is used if there is a risk to your health, 

e.g. due to an electric shock.

  The symbol with the exclamation mark in the triangle is used to indicate important 

information in these operating instructions. Always read this information carefully.

  The arrow symbol indicates special information and advice on operation.

Safety Instructions

Read the operating instructions carefully and especially observe the safety 

information. If you do not follow the safety instructions and information 

on proper handling in this manual, we assume no liability for any resulting 

personal injury or damage to property. Such cases will invalidate the warranty/

guarantee.

•  The device is not a toy. Keep it out of the reach of children and pets.
•  Do not leave packaging material lying around carelessly. This may become 

dangerous playing material for children.

•  Protect the appliance from extreme temperatures, direct sunlight, strong jolts, high 

humidity, moisture, flammable gases, steam and solvents.

Do not mount the ambient air indicator in rooms with high dust level.

•  Do not place the product under any mechanical stress.
•  If it is no longer possible to operate the product safely, take it out of operation and 

protect it from any accidental use. Safe operation can no longer be guaranteed 

if the product:

 - is visibly damaged,
 - is no longer working properly,
 - has been stored for extended periods in poor ambient conditions or
 - has been subjected to any serious transport-related stresses.

•  Please handle the product carefully. Jolts, impacts or a fall even from a low height 

can damage the product.

•  Never touch the wall plug transformer with wet or damp hands. There is a risk of 

a lethal electric shock!

•  Do not pull the wall plug transformer from the socket by pulling on the cable.
•  Protect the cable of the wall plug transformer from sharp edges and do not bend it.

Summary of Contents for CO-60

Page 1: ...E CO 60 Best Nr 101300 Bestimmungsgem e Verwendung Die Raumluft Anzeige CO 60 ist ein station res Messger t zur Erfassung der Kohlendioxid Konzentration CO2 inderUmgebungsluftaufBasisdergenauenundlang...

Page 2: ...gentliche Reinigung wartungsfrei Verwenden Sie keine aggressiven Reinigungsmittel Alkohol oder andere chemische L sungsmittel da diese zu Sch den am Geh use und zu Fehlfunktionen f hren k nnen Verwend...

Page 3: ...ntration CO2 in the ambient air with an exact and long term stable measuring method of the NDIR Non Dispersive Infrared Spectroscopy The meter is intended for monitoring the carbon dioxide level in th...

Page 4: ...ee cloth Do not apply too much pressure on the display to avoid scratch marks Disposal Electronic devices are recyclable waste and must not be disposed of in the household waste At the end of its serv...

Page 5: ...ANT CO 60 N de commande 101300 Utilisation pr vue L indicateur de concentration de l air ambiant CO 60 est un instrument de mesure stationnaire servant mesurer la concentration en dioxyde de carbone C...

Page 6: ...etien N utilisez pas de produits de nettoyage abrasifs d alcool friction ou autre produit chimique ceux ci risqueraient d ab mer le bo tier et de causer des dysfonctionnements Nettoyez le produit avec...

Page 7: ...ir meettoestel voor het meten van de concentratie kooldioxide CO2 in de omgevingslucht en wel met behulp van de nauwkeurige en over een langere periode stabiele meetmethode NDIR niet dispersieve infra...

Page 8: ...is het apparaat onderhoudsvrij Gebruik in geen geval agressieve schoonmaakmiddelen reinigingsalcohol of andere chemische oplossingen omdat deze schade aan de behuizing of storingen kunnen veroorzaken...

Reviews: