14. Specifications
Display ..............................................................2000 counts
Measuring rate ..................................................approx. 2 - 3 measurements/second
Measuring line length .......................................approx. 75 cm each
Measuring impedance ......................................>10 MΩ (V range)
Operating voltage .............................................9 V block battery
Operating conditions .........................................0 °C to 40 °C, max 75% rH, non-condensing
Operating altitude .............................................max 2000 m
Storage temperature .........................................-10 °C to +50 °C
Weight ..............................................................approx. 200 g
Dimensions (L x W x H) ....................................137 x 72 x 35 (mm)
Measurement category .....................................CAT III 250V
Degree of contamination ..................................2
1
Measurement tolerances
Accuracy in ± (% of r display error in counts (= number of smallest digits)). These accuracy readings are
valid for one year at a temperature of +23 °C (± 5 °C) and a relative humidity of less than 75% (non-condensing).
DC voltage, overload protection 250 V
Range
VC130-1
Accuracy
Resolution
200 mV
±(0.5% + 8)
0.1m V
2000 mV
1 mV
20 V
0.01 V
200 V
0.1 V
250 V
±(0.8% + 8)
1 V
AC voltage (40 - 400 Hz), overload protection 250 V, mean value detection with sinusoidal signal
Range
VC130-1
Accuracy
(5 - 100% of measurement
range)
Resolution
200 V
±(1.5% + 8)
0.1 V
250 V
1 V