background image

1. INTRODUCTION

 

Content  of  this  manual  is  intended  to  facilitate  the  operation  and  use  of 

domestic circulators as much as possible. It contains information on the safe installation 
and use of the product. It is recommended that you read the instructions carefully, as the 
lack of proper knowledge  regarding  the assembly and operation  of the device may 
cause damage to the pump or personal injury caused by moving pump parts, leaking 
liquids or improper electrical connections.

 

Pumps are always checked thoroughly before leaving the factory. For some 

models, individual parts or accessories may be packed separately, so make sure that all 
parts of the device are delivered at the time of purchase, and check that there are no 
signs of damage.

 

ATTENTION:

  Before  purchasing,  carefully  check  the  pump  for  signs  of 

damage. All types of mechanical damage can cause health and life risks and are not 
covered by the warranty.

2. USAGE

 

OPTI EKO pumps are intended for forcing circulation in heating installations. 

They can be used in single and two-pipe installations as well as when installing floor 
heating.  The  pump  is  equipped  with  a  system  that  automatically  adjusts  the  pump 
characteristics to the installation in which it works.

 

Thanks to the permanent magnet pump design and the electric motor powered 

by the frequency converter, the pump can adapt its operation to the current demand, 
thus  reducing  energy  losses.  Its  design  and  functional  features  meet  the  latest 
standards (EuP Directive), and the energy efficiency ratio EEI is less than 0.2 or 0.23 
(depending on the model).

3. TECHNICAL PARAMETERS

[email protected] (58) 341-05-06 | [email protected] (58) 341-38-80 | [email protected] (22) 100-42-99

Input voltage

230 V, -10% ÷ +6%, 50Hz

Relative humidity

95%

Sound pressure level

Lower than 43 dB

Ambient temperature

0ºC ÷ +40ºC

Liquid temperature

+2ºC ÷ +100ºC

Power

Qmax

Hmax

4,5m (ECO 25-40/180 ) / 6m (OPTI 25-60/180 )

Max. Working pressure

10bar

Protection

IP42

Depending on the model, check the nameplate

Summary of Contents for OPTI ECO

Page 1: ...NUAL VOLT POLSKA Sp z o o ul Grunwaldzka 76 81 771 Sopot www voltpolska pl ECONOMIC CIRCULATING PUMPS sales voltpolska pl 58 341 05 06 przemek voltpolska pl 58 341 38 80 bartek voltpolska pl 22 100 42 99 ...

Page 2: ... covered by the warranty 2 USAGE OPTI EKO pumps are intended for forcing circulation in heating installations They can be used in single and two pipe installations as well as when installing floor heating The pump is equipped with a system that automatically adjusts the pump characteristics to the installation in which it works Thanks to the permanent magnet pump design and the electric motor power...

Page 3: ...hout obtaining authorization for this release the Guarantor from any kind of liability ź After completing the work switch on all protective and safety devices again Pump should be installed in a straight section of the installation Shut off valves must be fitted on the suction pipe as well as the supply pipe Please note that the system pressure does not exceed the permissible operating pressure of t...

Page 4: ...ska pl 58 341 05 06 przemek voltpolska pl 58 341 38 80 bartek voltpolska pl 22 100 42 99 Recommended Alternative A Floor heating AUTO B Two pipe installation AUTO C One pipe installations Lowest characteristics at proportional pressure control PP1 The highest characteristics when regulating proportional pressure PP2 Installation type Poz Pump setting Highest characteristics w ith constant pressure...

Page 5: ...ted the pump will automatically change its performance between normal operation and night reduction Changing the operating mode between night reduction and normal operation depends on the temperature of the liquid flowing in the pipe The pump automatically switches to night reduction mode when the sensor registers a drop in liquid temperature by more than 10 15 C in about 2 hours The temperature dr...

Page 6: ... according to the following diagram 6 STORAGEAND MAINTENANCE User is obliged to supervise the technical condition of the pump observing all safety rules mentioned above The pump requires no special maintenance during operation The desired pump performance characteristics are obtained by modifying the engine speed Modifications can be made while the pump is running using a switch on the terminal box...

Page 7: ...and as a result of improper use or the instructions in the operating manual ź damage resulting from improper storage or maintenance ź damage caused by pumping sand ź damage caused as a result of connecting to the electrical installation that does not meet the conditions contained in the operating instructions or does not comply with applicable power standards ź damage caused as a result of tamperi...

Page 8: ...costs of the repair Please attach a copy of the purchase document receipt or FV to the complaints sent and if possible a printed and completed complaint form from www voltpolska pl Full and current regulations of service repairs can be found on our website www voltpolska pl sales voltpolska pl 58 341 05 06 przemek voltpolska pl 58 341 38 80 bartek voltpolska pl 22 100 42 99 DATE OF PURCHASE SHIPME...

Reviews: