Reverse polarity hook up 

      ON 

Bad batteries cannot be recharged 

      Flashing for 12V batteries 

Flashing for 24V batteries

 

 

Charging rate select: 

Dcharging rate is 4A, selecting the 8A charging rate by pressing the MODE button; 

 

Charging status LED indicators to display the battery charging level 25%, 50%, 75% and 100%. 

 

 

3. 

  Disconnect the AC power cord from the AC power outlet when fully charged. Then disconnect the connection with the battery. 

    

Note:   

 

ALWAYS disconnect the AC power cord from the AC power outlet before connecting (or disconnecting) the charger to (or from) the battery. 

CHARGING PHASES 

1. Diagnosis & Recovery 

As soon as charging instruction is given to the charger, the unique function automatically checks status of battery (detects voltage). If a deeply 

discharged battery's voltage is over 4.5V ± 0.5V (for 12V battery) or 16V ± 0.25V (for 24V battery), charger begins charging with 1.5A  low 

current to recover it, which terminates when voltage reaches to 10.5V ± 0.25V for (12V battery) or 21V ± 0.25V (for 24V battery) at the 

beginning of the process, the charger skips low current charging and it switches over to charging mode. 

 

2. Bulk Charging 

80% of energy is returned in this phase of charging. Here charger performs in multi-stages: 

 

For 24V battery 

Select 4A slow charge or 8A fast charge rate according to practical need; 

 

For 12V battery

 

Select 4A slow charge, 8A fast charge rate according to practical need; 

 

3. Absorption 

Use of a constant high current for extended periods of time risks gassing the battery, therefore a constant low charging current is given at 1.5A 

to raise voltage from 28.2V to 28.8V (for 24V battery) and 14.1V to 14.4V (for 12V battery). In this phase complete charging up to almost 100% 

is achieved. Charger switches to trickle charge phase after sensing that the battery is truly fully charged. 

 

4. Maintenance Charge 

As charger continuously monitors the terminal voltage in order to determine if a maintenance charging should be initiated, if the battery is 

loaded and/or terminal voltage falls below 25.6V (for 24V battery) or 12.8V (for 12V battery), the charger starts maintenance charging pulse at 

constant 1.5A until voltage reaches to 28.8V (for 24V battery) or 14.4V (for 12V battery). Now maintenance charging is discontinued. Cycle of 

trickle charging and maintenance charging is repeated indefinitely to keep battery in good condition when it is not in use and enables charger to 

be left connected indefinitely. 

 

5. Supply 13.6V   

a) 

Maintenance of 12V SLA batteries:

  This  mode  is  suitable for maintenance of 12V batteries with capacity range from 14-230Ah. The 

charger delivers a constant output  of 13.6V/4A. This is maintenance mode for applications where maximum capacity from the battery is 