4.3
MIX PUMP HOSE REPLACEMENT
Mix pump hose must be replaced when tubing cannot be
further repositioned (every four to eight weeks). Failure
to comply will result in hose failure and possible pump
damage. Follow the steps below to replace the hose:
A.
Run cleaning solution through pump.
B.
Turn the pump off and relieve any pressure by
opening the spigot.
C.
Disconnect the mix pump hose at each end.
D.
Grasp the discharge hose end with one hand and
turn the pump on. Pull down on the hose until all
of the remaining hose is removed from the pump.
Turn pump off.
E.
Rotate pump roller assembly so one roller is at
the 6:00 position.
F.
Use a brush that fi ts in the opening and clean the
pump roller assembly, fi rst with detergent water
and then clear water.
G.
Connect the new mix pump hose to the pickup
hose adapter using the small clamp.
H.
Feed one end of the mix pump hose into the
pickup hose side (left) of the black cover.
NOTE
Feed the tube into the clamp so the natural curve of
the tube is towards the outside of the black cover.
This prevents the hose from looping around the
black cover twice.
I.
Gently push the hose into the black cover until it
begins to feed.
J.
Allow the hose to feed itself through the pump
until about 6" (15cm) remains on the entering
side and turn the pump off.
L.
Connect the mix pump hose to the elbow fi tting
(located on the left side of the mix line manifold)
using a small hose clamp. Be careful not to twist
the mix hose.
M.
Turn the pump on.
N.
Allow the remaining 6" (15cm) of tubing to feed
through the pump until the hose adapter prevents
further feeding and turn the pump off.
CAUTION
Risk of Product Damage
Air/Mix Tee must remain below the black cover
clamp. If the Tee is above the pump, the mix may
drain into the air compressor, resulting in pump
damage.
P.
Connect the free end of the mix pump hose to the
3-way Tee. When all connections are complete,
the 3-way Tee must be lower than the black pump
housing.
Q.
The pump is now ready to sanitize.
NOTE
The hose timer must be reset each time the hose is
repositioned or replaced to keep an accurate record
of the hose service time.
4.4
FINE CONSISTENCY ADJUSTMENT
Product consistency can be adjusted on the Fine Consis-
tency Adjustment screen. To get to the Fine Consistency
Adjustment Screen, press the right arrow then the SEL
button from the Current Status screen. Then move the
cursor to the Fine Consistency Adjustment option and
press the SEL button.
Increasing the Fine Consistency number increases the
product consistency (fi rmer product). The Consistency
Limits show the Fine Consistency adjustment added to
the Consistency number.
Figure 4-2 Pump Hose Reposition
Pickup
End
12” to 14”
Figure 4-2 Fine Consistency Adjustment
Summary of Contents for Stoelting O431I2F
Page 1: ...Model O431I2F OPERATORS MANUAL Manual No 513678 Rev 1 ...
Page 2: ......
Page 22: ...Owner s Manual 513678 16 O431 I2 Model Machines ...
Page 26: ...Owner s Manual 513678 20 O431 I2 Model Machines ...
Page 32: ...Owner s Manual 513678 26 O431 I2 Model Machines ...
Page 36: ...Owner s Manual 513678 30 O431 I2 Model Machines ...