Owner’s Manual #
6
O431 I2 Model Machines
5.
Place three mix bags into the mix container.
6.
Connect the bag adapter attached to the left side
of the manifold (closest to the mix outlet) to the
mix bag in the back of the mix container.
7.
Connect the bag adapter attached to the middle
of the manifold to the mix bag in the middle of
the mix container.
8.
Connect the bag adapter attached to the right
side of the manifold (farthest from the mix outlet)
to the mix bag in the front of the mix container.
When Using Bag Connection System (BCS) with One
or Two Bags (optional kit #2183987):
When connecting one or two bags, the manifold adapt-
ers must be installed closest to the manifold outlet and
the manifold plug(s) must be placed farthest from the
manifold outlet.
1.
Connect 3/8” (9,5mm) ID plastic food grade tubing
to a bag adapter. Secure with hose clamps.
2.
Slide the hose clip over the free end of the tubing.
Attach the free end of the tubing to a manifold
adapter. Secure with a large hose clamp.
3.
Push the manifold adapter with spring and
valve into the left port (nearest
the manifold outlet) of the mix
inlet manifold and secure with
retaining clip. (See Figure 2-5).
4.
If using two mix bags, repeat
steps 1 to 3 for the middle port.
5.
Install a manifold plug into each
empty inlet and secure with a
retaining clip.
6.
Place the mix bag(s) into the mix
container.
7.
Connect the bag adapter
attached to the left side of the
manifold (closest to the mix
outlet) to the mix bag in the back
of the mix container.
2.6 INTELLITEC2™ SETUP
A.
Disassemble, clean, lubricate
and assemble the machine
following the steps in Sections
3.3-3.7.
B.
Fill the mix containers in the
cabinet with sanitizer.
C.
Connect power to the machine
and press the Main Power On/
Off button.
D.
Press the Pump On/Off button
when the Current Status screen
is displayed
Figure 2-5 Bag Connection System (Optional)
Bag Adapter
Manifold
Adapter
Retaining
Clip
Mix Inlet
Manifold
Manifold
Plug
MOTOR CALIBRATION
Before starting the motor calibration, be sure there is
sanitizer in the freezing cylinder.
A.
Press the On/Off Left or On/Off Right button. The
Motor Calibration screen will be displayed.
B.
Move the cursor over the Left side and press the
SEL button then move the cursor over the Right
side and press the SEL button.
NOTE
The motor calibration can be done for both sides
simultaneously.
Figure 2-6
Summary of Contents for Stoelting O431I2F
Page 1: ...Model O431I2F OPERATORS MANUAL Manual No 513678 Rev 1 ...
Page 2: ......
Page 22: ...Owner s Manual 513678 16 O431 I2 Model Machines ...
Page 26: ...Owner s Manual 513678 20 O431 I2 Model Machines ...
Page 32: ...Owner s Manual 513678 26 O431 I2 Model Machines ...
Page 36: ...Owner s Manual 513678 30 O431 I2 Model Machines ...