![Vollrath Stoelting M202 Operator'S Manual Download Page 8](http://html1.mh-extra.com/html/vollrath/stoelting-m202/stoelting-m202_operators-manual_1045873008.webp)
Owner’s Manual #513666
2
M202B Model Machines
1.2 SPECIFICATIONS
M202B A/C
M202B A/C Remote
M202B W/C
Dimensions
Machine
with crate
Machine
with crate
Machine
with crate
width
27-1/2’’(69,9 cm)
48’’(121,9 cm)
27-1/2’’(69,9 cm) 42-1/2’’(108,0 cm) 27-1/2’’(69,9 cm) 42-1/2’’(108,0 cm)
height
59’’(149,9 cm)
69-1/4’’(175,9 cm) 57-1/2’’(146,1 cm)
67’’(170,2 cm)
57-1/2’’(146,1 cm)
67’’(170,2 cm)
depth
40-3/8’’(102,6 cm)
60’’(152,4 cm)
32’’(81,3 cm)
48’’(121,9 cm)
32’’(81,3 cm)
48’’(121,9 cm)
Weight
845 lbs
(383,2 kg)
1232 lbs
(558,8 kg)
645 lbs
(292,5 kg)
675 lbs
(306,1 kg)
845 lbs
(383,2 kg)
1232 lbs
(558,8 kg)
Electrical
1 PH
3 PH
1 PH
3 PH
1 PH
3 PH
circuit ampacity
(per barrel)
20A
15A
15A
15A
20A
15A
overcurrent protection
device (per barrel)
25A
15A
15A
15A
25A
15A
Compressor
6,690 Btu/hr
Drive Motor
Two - 2 hp
Cooling
Self contained air cooled units require
6” (15,2 cm) air space on sides and 24”
(60,9 cm) at the back.
Air cooled units require one remote
condensing unit (with compressor)
per barrel. Condensing units for 60Hz
machines ship from the factory with
20 lbs of refrigerant for up to a 50’ line
set. Add 1 lb of refrigerant for every
10’ increase to the line set. Line set
max 100’. (Condensing units for 50Hz
machines do not ship charged and
require 20 lbs of refrigerant)
Water cooled units are self contained
and require a Standard Hose Adapter
water fitting and a 1/2” OD drain fitting
for each barrel.
Hopper Volume
Two - 5.4 gallon (20,57 liters)
Capped Refrigeration Lines
Piercing Union Refrigeration Lines
285110 (1 PH) & 285111 (3 PH)
285114 (1 PH) & 285115 (3 PH)
Dimensions
Condenser
Condenser
width
39-1/8’’ (99,4 cm)
39-1/8’’ (99,4 cm)
height
19-3/4’’ (50,2 cm)
19-3/4’’ (50,2 cm)
depth
28-1/4’’ (71,7 cm)
28-1/4’’ (71,7 cm)
Weight
1 PH: 223 lbs (101,2 kg) / 3 PH: 228 lbs (103,4 kg)
1 PH: 223 lbs (101,2 kg) / 3 PH: 228 lbs (103,4 kg)
Electrical
1 Phase, 208-230 VAC, 60Hz 3 Phase, 208-230 VAC, 60Hz 1 Phase, 208-230 VAC, 60Hz 3 Phase, 208-230 VAC, 60Hz
circuit ampacity
15A minimum
15A minimum
15A minimum
15A minimum
overcurrent protection
device
20A maximum
15A maximum
20A maximum
15A maximum
Refrigerant
R-448A
R-448A
Charge
20 lbs. (Charged at Factory)
20 lbs. (Charged at Factory)
Refrigerated Line
Sizes
Liquid Line - 3/8”
Suction Line - 7/8”
Liquid Line - 3/8”
Suction Line - 7/8”
1.3 REMOTE CONDENSING UNITS SPECIFICATIONS
Model numbers ending with “SP0R” or “SSIR” have piercing unions on the refrigeration lines. The line set and remote
condensing unit need piercing unions to connect to the machine.
All other models are capped and require the refrigeration lines to be routed on site. The remote condensing units
are also capped.
One remote condensing unit per barrel.