Service Manual #513659
18
Model F231
H. Time and Date
The Time and Date menu shows the time and date set-
tings. The Manager and Technician levels can change the
time and date by using the Modify Time and Date option.
4.6 UTILITIES SCREENS
The Utilities menu gives access for various settings and
operations in the control. The Utilities menu is available
to the Technician and Manager levels. The Manager level
will only have access to the
fi
rst screen. The Technician
level has access to both screens.
NOTE
Entering the Utilities (2 of 2) screen automatically
shuts off the freezing cylinders.
A. Product Selection
F. Storage Settings (2 of 2)
This Storage Settings menu contains storage refrigeration
parameters and is available to the Manager and Techni-
cian levels. Press the left arrow to go to the
fi
rst screen.
The
Storage Max On
setting is the maximum time that
a storage refrigeration cycle will run.
The
Storage Recovery
setting is the minimum time
between storage refrigeration cycles if the Storage Max
On time ends the cycle.
The
Storage Too Warm
values are the temperature and
amount of time. When the temperature is above the set
temperature for the set period, the Storage too Warm
message will be displayed.
G. User Preferences
The User Preferences menu contains language options,
temperature units, service contact information and touch-
pad lockup. The screen is available to the Manager and
Technician levels.
The
Language
setting changes the language displayed.
English and Polish are the only languages currently
available.
The
Temperature Units
setting changes the units dis-
played to Fahrenheit or Celsius.
The
Service Contact Information
option is used to change
the service contact details including service company
name and number and machine serial number.
User Preferences
_ Language English
_ Temp Units Farenheit(°F)
_ Service Contact Information
_ Contact Information USB Update
Time and Date
Time 00:00:00 AM
Date 00/00/00
Daylight Savings Off
Clock Type 12 HR
Date Format
_ Modify Time and Date
Utilities (1 of 2)
_ Adjust LCD Contrast
_ Touchpad Lockup
_ Export Machine Stats
_ Clean Options
Next Utilities Menu
Storage Settings (2 of 2)
_ Storage Max On 00 min
_ Storage Recovery 0 min
_ Storage Too Warm 00.0°F
_ Storage Too Warm 000 min
Utilities (2 of 2)
_ Testing and Manual Operation
_ Unit Calibration
_ Clear Log Data
_ Restore Factory Defaults
_ Restore Motor Table Defaults
_ Reset Unit Configuration
Product Selection
Cylinder Right
_ Current Product Type 0
CutOut Consistency 000
CutIn Consistency 000
Press Set to change selection
Press Sel to accept selection
Summary of Contents for Stoelting F231