8
2.2 SHIPMENT AND TRANSIT
The machine has been assembled, operated and inspected
at the factory. Upon arrival at the final destination, the
complete machine must be checked for any damage which
may have occurred during transit.
With the method of packaging used, the machine should
arrive in excellent condition. THE CARRIER IS RESPON-
SIBLE FOR ALL DAMAGE IN TRANSIT, WHETHER VIS-
IBLE OR CONCEALED. Do not pay the freight bill until the
machine has been checked for damage. Have the carrier
note any visible damage on the freight bill. If concealed
damage and/or shortage is found later, advise the carrier
within 10 days and request inspection. The customer must
place claim for damages and/or shortages in shipment with
the carrier. Stoelting cannot make any claims against the
carrier.
2.3 MACHINE INSTALLATION
Installation of the machine involves moving the machine
close to its permanent location, removing all crating,
setting in place, assembling parts, and cleaning.
A.
Uncrate the machine.
B.
Accurate leveling is necessary for correct drainage
of the freezing cylinder and to insure correct
overrun. Place a bubble level on top of the machine
at each corner to check for level condition. If
adjustment is necessary, level the machine by
turning the bottom part of each leg in or out. Then
separate machine base gasket and install with
seam to the back and angle to the top.
C.
If the machine is equipped with an air cooled
condenser, correct ventilation is required. The right
side of the machine is the air intake and left side
discharge. Both sides must have 3" clearance the
top requires 10" of clearance.
CAUTION
Failure to provide adequate ventilation will void war-
ranty.
D.
Place the OFF-ON switch in the OFF position.
E.
Connect the power cord to the proper power
supply. Check the nameplate on your machine for
proper supply. The unit must be connected to a
properly grounded receptacle. The electrical cord
furnished as part of the machine has a three prong
grounding type plug (Fig. 2-3). The use of an
extension cord is not recommended, if necessary
use one with a size 12 gauge or heavier with ground
wire. Do not use an adapter to get around grounding
requirement.
WARNING
Do not alter or deform electrical plug in any way.
Altering the plug to fit into an outlet of different con-
figuration may cause fire, risk of electrical shock,
product damage and will void warranty.
F.
Install the drip tray, drain tray, hopper cover and
other miscellaneous parts on the machine.
Figure 2-2 Space and Ventilation Requirements
115V
20 Amp
Figure 2-3 Electrical Plug
208/230V
15 Amp
Summary of Contents for Stoelting E111I
Page 1: ...Model E111I F111I SERVICE MANUAL Manual No 513663 Nov 2010...
Page 2: ......
Page 24: ...18...
Page 26: ...20 Figure 4 2 IntelliTec Control Menu Settings...
Page 46: ...40...
Page 57: ...51 8 9 WIRING DIAGRAMS...
Page 58: ...52...
Page 59: ...53...
Page 60: ......