![VOLKTEK INS-801 User Manual Download Page 13](http://html1.mh-extra.com/html/volktek/ins-801/ins-801_user-manual_1045690013.webp)
13
Procedure for Connecting DC Power:
For shipping, the removable green Contact Block may be
detached from the six-pin terminal contact point. It may
be easier to attach the DC wires to the green Contact
Block if it has first been unplugged from the terminal
contact point on the switch.
A. On the Power Contact Block, use a flathead
screwdriver to loosen the screws of the primary
power pins (labeled PWR +/-) and then insert the
negative and positive DC wires. Tighten until
snug.
B. For the back-up DC connection, follow the same
procedure as above. Attach power wires to the
Contact Block (in the position marked RPS +/-)
C. If the Contact Block is not already inserted into
the block receptor of the Switch, do so now.
D. Assure your DC power supply is stable and clean
before applying DC power to the Switch.
Ethernet Connections
The INS-801 Industrial Fast Ethernet Switch has five
10/100Base-TX Ethernet ports. The 10/100Base-TX
ports are located on the Switch’s front panel and are
used to connect to Ethernet-enabled devices.