9.7
9.7.1
9.7.2
9.7.3
9.8
9.9
9.9.1
9.9.2
9.9.3
9.9.4
9.9.5
9.9.6
Red indicator lam p'Tailure"
The red indicator lamp (c) lights up if there is a failure.
The reason for such an indication is, for example, if no gas is available or
if there is air in the gas supply system, triggering the excess temperature
monitor. To unlock, switch off the appliance, wait 5 minutes, and switch
on again.
In the event of faults, always contact Truma Service (they may be
contacted through your local Auto-Sleeper dealer).
Truma Control Panel (Electrical operation 230 V, 450 W)
d = Switch On/Off
Electrical Operating Instructions
Attention:
Never operate the water heater without water in it.
Switch the switch (d) on the Truma control panel to "On". The indicator
lamp indicates that the electrical water heating is switched on.
Note:
The water temperature is fixed at approx. 70°C. For a faster
heating up period the appliance can be simultaneously operated on both
gas and electrical power.
Maintenance
Use wine vinegar for de-scaling the water heater; this should be
introduced into the appliance via the water supply. Allow the product to
react and then thoroughly flush out the appliance with plenty of fresh
water. To sterilise the water we recommend "Certisil-Argento". Your local
Auto-Sleeper dealer will obtain this on your behalf. Other products,
particularly those containing chlorine are unsuitable.
Note:
The water tank in the Truma-Ultrastore is of high quality stainless
steel. The plastic elbow water connections and the safety/drain valve fulfil
the EC guidelines for food quality in plastic parts (90/128/EEC).
In order to avoid the colonization of micro organisms, Truma recommend
heating up the tank to 70°C at regular intervals and not using the water as
drinking water.
-
4 7
-