GENERAL SAFETY NOTES
If the gas system is leaking or if there is a smell of gas:
-extinguish all naked fames
do not smoke
switch off the appliances
shut off the gas cylinder
open the windows
do not actuate any electrical switches
have the entire system checked by an expert
1. Repairs may only be carried out by an expert.
Attention:
A new O-ring must always be installed after dismantling the exhaust
duct!
2. Any alteration to the appliance (including exhaust duct and cowl) or the use of
spare parts and accessories which are important to the function of the heater and
which are not original Truma parts, as well as the non-observance of the
installation and operating instructions, will lead to the cancelling of the guarantee
and exclusion of liability claims. It also becomes illegal to use the appliance, and
in some countries this even makes it illegal to use the vehicle.
3.
The operating pressure for the gas supply is 30 mbar (or 28 mbar butane/37
mbar propane) and must correspond to the operating pressure of the
appliance (see name plate).
4.
Do not operate the appliance when refuelling the vehicle and when in the
garage.
5. During the initial operation of a brand new appliance (or after it has not been
used for some time), a slight amount of fumes and smell may be noticed for a
short while. This can be remedied by running the heater at maximum output and
ensuring adequate room ventilation.
6. If the burner makes an unusual noise or if the flame lifts off, it is likely that the
regulator is faulty and it is essential to have it checked.
Technical Data
Type of gas:
Liquid gas (propane/butane)
Operating pressure:
30 or 50 mbar (refer to nameplate)
Rated thermal output:
High setting: 2400 W. Low setting: 1200 W.
Gas comsumption:
High setting: 200 g/h. Low setting 100 g/h.
A irflo w rate:
High setting: approx. 130 m3/h. Low setting: approx. 77m3/h.
Current input at 12 V:
High setting 1.1 A. Low setting 0.6 A.
Current input at 24 V:
High setting 0.7 A. Low setting 0.4 A.
Standby:
0.01 A
Weight:
approx. 4.7 kg
Declaration of Conformity
The Trumatic E 2400 has been DVGW-tested and complies with the EC gas appliance
guidline (90/396/EEC) as well as with the associated EC guidelines. The following
CE
Product Ident. Number:
is available for EU countries:
CE-0085A00008
General design approval of the federal office for motor vehicles: S 260
-32-
www.vwT4camper.info - a useful website for owners and enthusiasts of VW T4 Transporter Campervans