MiniFlow S Applicator

Calibration

for forage harvesters - using one nozzle

CALCULATING THE FLOW RATE REQUIRED

Measure the time taken to fill a trailer.  

Only include actual pick-up time, not time taken turning, etc.

Calculate the flow rate required as follows:
1.  Harvest rate (tonnes/min)  =   weight of grass (tonnes) 
                                                                  time to fill trailer (mins)
2.  Flow rate (litres/min)  =  harvest rate (tonnes/min)  x  required application rate (litres/tonne) 

CHOOSING THE CORRECT NOZZLES AND CONTROL BOX SETTING

Choose the flow rate in the table below that is closest to the flow rate determined above. Then read off the nozzle size 
(Hypro Flat Fan 110° nozzle) and control box setting needed to maintain the correct flow rate. For example, to achieve a 
flow rate of 1.50 litres/min will require a single Light Blue nozzle and the control box set at 6.

NB. This table is intended as a guide only.  These optimum rates can be affected by a poor power supply, an 

overlong power supply cable or delivery tube, a kinked or dirty delivery tube and dirty nozzles.

 

You should 

always check the flow rate yourself.

  

 

                

* LP nozzles are available on request (from Selmech Supplies)

Control

Box

Setting

Blue

(VP110-03)

Brown

(VP110-05)

Light Blue

(F110-10)

Black

(F110-20)

1 Hypro Flat Fan Nozzle

3

0.38

0.67

1.00

1.37

1.88

4

0.52

0.75

1.25

1.58

2.13

5

0.55

0.86

1.37

1.77

2.3

6

0.63

0.97

1.50

2.00

2.48

7

0.68

1.07

1.58

2.13

2.72

8

0.73

1.35

1.75

2.40

3.15

LP150*     

Flow Rate (litres/min) – 1 nozzle

-3-

Summary of Contents for ECOSYL Miniflow S

Page 1: ...aximum output is being produced by the tractor otherwise pump output will be reduced and damage to the applicator may result 1 Fit the pump unit into an upright 200 litre plastic drum placed as requir...

Page 2: ...e from the Calibration Chart and fit into the nozzle body ensure a tight fit Check the PVC tubing for damage and kinks and that the connections are secure and the right way round never run the pump in...

Page 3: ...0 nozzle and control box setting needed to maintain the correct flow rate For example to achieve a flow rate of 1 50 litres min will require a single Light Blue nozzle and the control box set at 6 NB...

Page 4: ...ned above Then read off the nozzle size Hypro Flat Fan 110 nozzle and control box setting needed to maintain the correct flow rate For example to achieve a flow rate of 1 5 litres min will require 2 B...

Page 5: ...0 3 litres min will a single yellow nozzle and the control box set at 5 NB This table is intended as a guide only These optimum rates can be affected by a poor power supply an overlong power supply c...

Page 6: ...HEIR MIXTURES ARE USED Fault Possible causes Remedy Wires incorrectly connected or damaged Check crocodile clips attached properly to the battery Check control box wires Fuse blown Replace fuse Check...

Page 7: ...ield Industrial Estate Salisbury Wilts SP2 7YS UK Tel 44 0 1722 413440 Fax 44 0 1722 413466 Email admin selmechsupplies co uk Miniflow S MB Applicators 7 MF1801 MF1805 MF1806 MF1803 MF1804 MF1808 MF18...

Reviews: