REPAIRS & SPARES
S
ELMECH SUPPLIES, 19 Norton Enterprise Park, Whittle Road, Churchfield Industrial Estate, Salisbury, Wilts, SP2 7YS,
UK. Tel: +44 (0)1722 413440. Fax: +44 (0)1722 413466. Email: [email protected].
TROUBLESHOOTING
WARRANTY
The Miniflow applicator is guaranteed against failure that can be attributed to faulty workmanship for a period of 12
months from the date of delivery provided that only recommended products are being used and the recommended
installation and maintenance instructions have been observed. Tampering with the components of the Miniflow
applicator will invalidate this guarantee. The applicator manufacturer, Selmech Supplies, reserves the right to change
the applicator specifications at any time without notice to allow for improvements or modifications to its designs.
THE WARRANTY IS VOID IF ACID PRODUCTS, EG: FORMIC, PROPIONIC OR SULPHURIC ACID
OR THEIR MIXTURES, ARE USED.
Fault
Possible causes
Remedy
Wires incorrectly connected or damaged
Check crocodile clips attached properly to the
battery. Check control box wires
Fuse blown
Replace fuse. Check for reasons blown before
restarting
Defective motor
Contact Selmech
Pump leads wrongly connected
Swop bullet connectors
Nozzle blocked
Clean nozzle
Tube kinked
Remove kink & re-route tubing
Drive shaft disconnected
Check and replace pin in gear
Drive shaft rotates with motor
Check and replace pin in gear
Nozzle blocked
Clean nozzle
Nozzle too small
Replace with larger nozzle
Tubing kinked
Remove kink and re-route tubing
Tubing split
Replace tubing
Wrong nozzle size and/or control box setting
Consult calibration chart – NB. Calibration chart
gives approximate flow rates only - carry out
proper calibration
Control box malfunctioning
Contact Selmech
Motor not running
Motor runs but no output
Wrong application rate
Motor runs/poor output
Drum empty
Fill drum
For more information on ‘Eco’ Applicators contact:
Freephone
| 0800 919808
Visit
| www.ecosyl.com
-6-