LATENT HEAT COLLECTOR fig’s. 40 & 41
Carry out component removal procedure as
described in 6.4. Remove the flue hood and fan
assembly as detailed in 6.16. Disconnect the
condense sensor wire from the sensor.
Fig. 40: disconnect and remove the inlet (1),
outlet (3) and condense pipes (2) from the
collector.
Fig. 41: unscrew and remove the 3 screws (1)
that secure the collector to the air chamber and
disconnect the collector (2) from the flue
connection. Replace in the reverse order ensuring
all seals are intact and located correctly.
6.28A D I S M A N T L I N G T H E L AT E N T H E AT
COLLECTOR (see fig. 42)
During routine servicing or maintenance, there
is no requirement to remove or dismantle the
collector, however should it be deemed
necessary to dismantle the collector, all seals
should be discarded and replaced with new ones.
6.29
CONDENSE TRAP REMOVAL (see fig. 43)
Carry out component removal procedure as
described in 6.4. Disconnect the flexible (outlet)
condense pipe from the condense trap (1).
Disconnect the rigid (inlet) condense pipe from
the condense trap (2). Locate and remove the
pins that secure the trap to the lower frame of
the boiler (3). Carefully remove the condense trap.
Replace in the reverse order.
If necessary remove the upper connection of the
pipe (4).