1
The Synergy is a high-efficiency system boiler with an
output of 28kW. The appliance - by design - incorporates
electronic ignition, circulating pump, expansion vessel,
safety valve, pressure gauge and automatic by-pass.
The Synergy is produced as room sealed, category
II2H3+ appliances, suitable for internal wall mounting
applications only. It is provided with a fan powered flue
outlet with an annular co-axial combustion air intake that
can be rotated - horizontally - through 360 degrees for
INTRODUCTION
various horizontal or vertical applications. The Synergy
range can also be used with the Vokera twin flue system.
The Synergy range is approved for use with C12 & C32
type flue applications.
This appliance is designed for use with a sealed system
only; consequently it is not intended for use on open
vented systems.
Fig. 1
Fig.1 General Layout
1
Safety Valve
2
Pressure Switch
3
Hydraulic manifold
4
Pump
5
Automatic Air Release Valve
6
Transformer
7
Main Burner
8
Electrode
9
Main Heat Exchanger
10
Latent Heat Collector
11
Condense Sensor
12
Flue Gas Analysis Test Point
13
Flue Outlet
14
Air Intake
15
Differential Analog Pressure Switch
16
Silicone Pressure Tube
17
Silicone Negative Pressure Tube
18
Fan Assembly
19
Combustion Chamber
20
Burner Temperature Control
21
Expansion Vessel
22
Gas Valve
23
Modulator Coil
24
Condense Trap
25
Status LED
26
Temperature Indicator
27
Central Heating Temperature Control
28
Combustion Switch
29
Timeclock Aperture (optional)
30
Pressure Gauge
31
Mode Selector Switch
5
6
9
11
12
13
14
23
1
2
3
4
7
8
10
15
16
17
18
19
20
21
22
24
25
26
27
28
29
30
31