Horizontal flue terminals and accessories
Part No.
Description
Length
520
521
522
523
524
525
526
527
528
529
Horizontal flue kit
Telescopic flue kit
Plume management kit
90-degree bend
45-degree bends (pair)
500mm extension
1000mm extension
2000m extension
Telescopic extension
Wall bracket pack (5)
900 mm
350 /530 mm
1370 mm
N/A
N/A
500mm
1000 mm
2000 mm
350 /730 mm
208mm
Reduction for additional bends
Bend
Reduction in maximum flue length for each bend
45° bend
90° bend
0.5 metre
1.0 metre
4.1 DELIVERY
Due to the weight of the appliance it may be necessary for
two people to lift and attach the appliance to its mounting.
The appliance is contained within a heavy-duty cardboard
carton. Lay the carton on the floor with the writing the
correct way up.
4.2 CONTENTS
Contained within the carton is:
●
●
●
●
●
The boiler
●
●
●
●
●
The wall bracket
●
●
●
●
●
Template
●
●
●
●
●
An accessories pack containing appliance service
connections and washers
●
●
●
●
●
The instruction pack containing the installation & servicing
instructions, user instructions, guarantee registration
card, and a 3-amp fuse.
4.3 UNPACKING
At the top of the carton pull both sides open – do not use
a knife – unfold the rest of the carton from around the
appliance, carefully remove all protective packaging from
the appliance, and lay the accessories etc. to one side.
Protective gloves should be used to lift the appliance, the
appliance back-frame should be used for lifting points.
4.4 PREPARATION FOR MOUNTING THE APPLIANCE
The appliance should be mounted on a smooth, vertical,
non-combustible surface, which must be capable of
supporting the full weight of the appliance. Care should be
exercised when determining the position of the appliance
with respect to hidden obstructions such as pipes,
cables, etc.
When the position of the appliance has been decided –
using the template supplied – carefully mark the position
of the wall- mounting bracket (see fig. 6) and flue-hole (if
applicable).
4.5 FITTING THE FLUE
The top flue outlet permits both horizontal and vertical flue
applications to be considered, alternatively, the Vokera
twin flue system can be utilised if longer flue runs are
required.
4.5.1 CONCENTRIC HORIZONTAL FLUE
(For concentric vertical flue, see 4.5.2).
(For twin flue applications, see 4.5.3).
The appliance can be used with either the Vokera condensing
60/100mm concentric flue system or the optional 80/
125mm concentric flue system.
NOTE
These instructions relate
only
to the Vokera condensing
60/100mm concentric flue system. For specific details on
the installation of the 80/125mm concentric flue system
please refer to the instructions supplied.
The appliance flue outlet elbow can be rotated through 360º
on its vertical axis. In addition the flue may be extended
from the outlet elbow in the horizontal plane (see 2.8). A
reduction must also be made to the maximum length (see
table below) when additional bends are used.
SECTION 4
INSTALLATION
Using the template provided, mark and drill a 115mm hole
for the passage of the flue pipe. The hole should be drilled
to ensure any condense fluid that forms, is allowed to
drain back to the appliance (see fig. 7A).
The fixing holes for the wall-mounting bracket should now
be drilled and plugged, an appropriate type and quantity
of fixing should be used to ensure that the bracket is
mounted securely. Once the bracket has been secured to
the wall, mount the appliance onto the bracket.
Fig. 7
terminal or
extension
outer
clamps