background image

3

THINGS YOU SHOULD KNOW

1.1

GAS APPLIANCE

Gas Safety (Installations and Use) Regulations.
In the interests of your safety and that of the
others it is a legal requirement that all gas
appliances are installed and correctly maintained
by a competent person and in accordance with
the latest regulations.

1.2

ELECTRICAL SUPPLY

Please ensure that this appliance has been
properly connected to the electrical supply by
means of a double pole isolator or un-switched
socket, and that the correct size of fuse (3 amp)
has been fitted.

Warning: this appliance must be earthed!

1.3

GUARANTEE REGISTRATION CARD

Please take the time to fill out your guarantee
registration card. The completed warranty card
should be posted within 30 days of installation.

GETTING STARTED

2.1

BEFORE SWITCHING ON

Before switching the appliance on, please
familiarise yourself with:

how to isolate the appliance from the gas,
water and electricity supplies;

how to check and top-up - if necessary - the
system water pressure;

the time clock;

any external thermostats and their functions;

the appliance controls.

2.2

APPLIANCE CONTROLS (fig. 1)

The appliance controls are concealed behind the
front flap. To gain access to the controls simply
pull the flap towards you in a downward motion.
The appliance is equipped with a simple keypad
that can be used to alter or display the following
functions:

the outlet flow temperature to the central heating
system;

switch on or off the boiler.

The pressure gauge shows the current pressure
of the system, the gauge should be set between
1 and 1.5 bar. When the appliance is operating
the gauge may rise or fall slightly, this is quite
normal. The minimum permissible level for the
safe and efficient operation of the appliance is 0.5
bar. Should the pressure fall below 0.5 bar, the
boiler may lockout.

Depending on the type of controls specified by
your installer you may have an integral Vokera
time clock fitted to the appliance, if so, instructions
can be found on page 6-7. If an external time
clock or programmer has been fitted, please refer
to the instructions supplied with such.

2.3

LIGHTING THE BOILER

Ensure the gas and electrical supply to the boiler
are turned on.
When there is a demand for heating via the timeclock
or programmer, the boiler will go through an ignition
sequence, whereby the burner will light.

If the appliance fails to ignite during the ignition
sequence, it will re-attempt ignition several times
before going to a lockout condition. Should this
occur, please allow a period of two minutes
before re-setting.

When the appliance reaches the set temperature,
the burner will go off for minimum period of
approximately 3 minutes.

When the programmer/time clock or external
thermostats heating request has been satisfied,
the appliance will switch off automatically.

2.4

ADJUSTING THE OPERATING PARAMETERS
(see fig. 1 & 1A)

Usually your installer will have adjusted the
operating parameters to suit your requirements,
however should you wish to alter the operating
parameters, please use the following procedure:

press the MODE button repeatedly until you
see a fixed decimal point in LED 1;

press the STEP button repeatedly until the parameter
that is to be adjusted is shown in LED 1;

use the adjustment buttons (+/-) to alter the
current setting as shown in LED 2;

press the STORE button to store the new
setting into the memory;

press the MODE button repeatedly until no
decimal point is shown in LED 1.

1.4

APPLIANCE LOG BOOK

A log book is supplied with the boiler. This important
document must be completed during the installation/
commissioning of your boiler. Failure to install and
commission the appliance in accordance with the
manufacturers instructions may invalidate the
warranty. This does not affect your statutory rights.

1.5

DIMENSIONS

HEIGHT

WIDTH

DEPTH

790 mm
450 mm
322 mm

1.6

CLEARANCES REQUIRED

ABOVE

BELOW

SIDES

FRONT

150 mm
150 mm

25  mm

600 mm

Summary of Contents for Eclipse ESS

Page 1: ...Users Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER ESS...

Page 2: ...3 Guarantee registration card 3 1 4 Appliance log book 3 1 5 Dimensions 3 1 6 Clearances 3 Getting started Page 2 1 Before switching on 3 2 2 Appliance controls 3 2 3 Lighting the boiler 3 2 4 Adjust...

Page 3: ...pe of controls specified by your installer you may have an integral Vokera timeclockfittedtotheappliance ifso instructions can be found on page 6 7 If an external time clock or programmer has been fit...

Page 4: ...tton until LED 1 shows 4 Use the adjustment buttons to alter the current value to the new value Press the STORE button to save the new value Press the MODE button until no decimal point is shown in LE...

Page 5: ...ly during the winter the system should be thoroughly drained of all water The gas water and electricity supply to the houseshouldalsobeturnedoff Formoredetailed advice contact your installer 3 5 HOW T...

Page 6: ...periods are set by sliding the black tappets adjacent to the time periods required to the outer edge of the dial The tappets that remain at the centre of the dial will be the OFF periods The smallest...

Page 7: ...will have to press the Select button once only to the on position if the boiler has been programmed to be on at that particular time 5 2 5 ADVANCING OR LOCKING PROGRAMME COMMANDS By pressing the Sele...

Page 8: ...e Tel 0141 945 6810 Spare Parts Tel 0141 945 6820 After Sales Service Tel 0870 333 0220 Vok ra Ireland West Court Callan Co Kilkenny Tel 056 55057 Fax 056 55060 Vok ra Ltd reserve the right to change...