background image

● Using the Adapter

  To capture an image within original focus range of the lens.
We recommend using the adapter with its focus ring ③ in the locked position.
Turn the focus ring ③ clockwise until it stops, and then slide the infinity lock lever 
⑤ in direction B in the figure to lock thus preventing it from rotating.
This prevents unintended focus shift from occurring when using scale focusing 
by the distance markings on the lens.

  To capture an image at a closer than the original minimum focusing distance 
of the lens, set the focus position on the lens to the minimum focusing distance, 
then focus by turning the focus ring ③ on the Adapter after unlocking the infinity 
lock lever ⑤ on the adapter by sliding it in direction A as in the figure.

Summary of Contents for VM-Z Close Focus Adapter

Page 1: ...INSTRUCTION MANUAL VM Z Close Focus Adapter Jul 2020 Ver 1 0 COSINA CO LTD ...

Page 2: ...Voigtländer mount adapters are designed to be used with Voigtländer lenses on various types of camera mounts ...

Page 3: ...esult in injuries and damage the equipment Keep the mount adapter and its accessories out of reach of children Do not leave the product in hot or cold temperature It might result in injuries and also damage the product Do not let the mount adapter ring support the whole weight of lens and camera When using big and heavy lens hold both camera and lens while in operation or transportation WARNING CA...

Page 4: ...Description of Parts Release button Lens mount index Focus ring Camera mount index Infinity lock lever A B ...

Page 5: ...ws lenses that are confirmed to work with the Close Focus Adapter without interference occurring between lens and the Close Focus Adapter or camera However the list is not a guarantee of the lens image quality when adapted Please note that warranty shall be voided and no manufacturer responsibility will be assumed if a lens other than the listed lenses is used with this Close Focus Adapter Using a...

Page 6: ... Attaching the lens to the Adapter Line up the index mark on the lens with the lens mount index on the Adapter and turn the lens clockwise until it locks Removing the lens from the Adapter Press the release button on the Adapter and turn the lens counter clockwise Removing the Adapter from the camera body Press the lens release button on the camera body and turn the Adapter clockwise ...

Page 7: ...e to lock thus preventing it from rotating This prevents unintended focus shift from occurring when using scale focusing by the distance markings on the lens To capture an image at a closer than the original minimum focusing distance of the lens set the focus position on the lens to the minimum focusing distance then focus by turning the focus ring on the Adapter after unlocking the infinity lock ...

Page 8: ...s Adapter Covered Image Size Full Frame Helicoid Extension 5 5mm Maximum Diameter Approx Ø69 0mm Weight Approx Ø105g Other Infinity Lock System Specifications Specification and information is subject to change without prior notice ...