HDSP-Series Operating Manual
28
Edition functions of the channels
HDSP-Series
3.9 Compr.: (Input compressor)
Here you set the Input compressor. This function is subdivided into six modules.
Setting the threshold value
■
Turn the
Encoder wheel
for setting the desired threshold value.
■ Select within a range from
-48.00
to
24.00 dBu
.
■ Press the
Encoder wheel
to view the next module.
Setting Attack
■
Turn the
Encoder wheel
for setting the desired Attack.
■ Select within a range from
1
to
10,000 ms
.
■ Press the
Encoder wheel
to view the next module.
Setting hold
■
Turn the
Encoder wheel
for setting the desired hold time.
■ Select within a range from
1
to
10,000 ms
.
■ Press the
Encoder wheel
to view the next module.