VOH SA
GU-04-06-01
PAViX - User Guide
Version 3.2
Created 10.2017
Page 40 / 48
In order to manage cases very close to the upper limit, the PAViX is equipped with an intelligent system that
takes into account human reaction time (0.1s). If the measured force exceeds the max tolerance by less than
10% in a time interval smaller than 0.1s before stop detection, the operation is considered successful.
Furthermore, as the displacement potentially applied during the 0.1s is low, the movement will not be damaged.
The force saved for traceability purposes is the force measured at the moment the stop comes into contact with
the spindle.
Figure 60: Smart detection, OK operation and details
The results for the setting operation are indicated as soon as the stop is reached or the max force is exceeded.
F
< Fmin
Fmin<
F
<=Fmax
F
> Fmax
Stop reached
Stop not reached
N/A
N/A
The results in red must be acknowledged by the operator using the right-hand side button. OK operations are
automatically validated after a period of 1.5 seconds.
6.3.4 Height corrections
If the “Ht correction” option has been enabled in the HMI when creating the programs or when the “Operator”
mode is selected in the staking-tool, it is possible to correct hand fitting heights by pressing and holding the
right-hand side button (as long as the current barrel position matches the current operation):
Figure 61
: Hand fitting in “Operator” mode (equivalent of the “Ht correction” option of the HMI)
When the button has been pressed and held down, the following page is displayed:
Figure 62: Height correction page
Simply turn the height setting wheel to perform the correction. The correction is displayed on the screen in mm.
Note:
Height correction is available in this program on a temporary basis. It is lost when the user leaves the
program.