Useful Tips
Useful
Tips
for trouble-free operation
8.5
Pump does not drive pulp or pumps out too little pulp
1
7
Possible Causes
Solutions
1.-
The impeller rotates
in the wrong direction.
2.-
Rotational speed.
•
If it is a three-phase pump,
switch phases.
•
Check that the rotation speed is
not too low and verify that the
discharge height of the system is
not too high.
3
.-
One or more valves are
in the wrong position.
•
Re-establish the valves that
are in the wrong position.
•
Replace valves if necessary.
•
Check that all valves are
positioned correctly and in
accordance with the liquid flow
rate.
•
Check that all valves open
correctly.
4
.-
It is difficult to turn the impeller by
hand.
•
Clean the impeller.
•
Clean the sump.
5
.-
The pipes are clogged.
•
Clean the pipes so that the liquid
flows smoothly.
6
.-
Pipes and joints leak fluid.
•
Look for leaks and seal them.
7.-
There are signs of wear on the
impeller, pump and casing.
•
Replace worn parts.
8.-
The liquid level is too low.
•
Check that the level sensor is
properly configured.
•
Depending on the type of
installation, add some element to
prime the pump, such as a
bottom valve.