Useful Tips
Useful
Tips
for trouble-free operation
8.3
Pump Starts and Stops in Quick Sequence
Possible Causes
Solutions
1.-
The pump is turned on due to
the return flow which fills the
sump back up to the start level.
2.-
The automatic contactor hold
function is malfunctioning.
Check if:
•
The distance between the start and
stop levels is sufficient.
•
The length of the discharge pipe
between the pump and the
discharge basin is sufficiently short.
Check if:
•
The contactor connections.
•
The voltage in the control circuit
in relation to the rated voltages
in the coil.
•
The operation of the start-stop
regulator.
•
Whether the voltage drop on the
line during the start-up
overvoltage
causes
the
automatic holding function of the
contactor to malfunction.
1
4
Summary of Contents for SSD Series