10TA Service Manual
TABLES & CHARTS
5/27/14
11-2
P18FXT SPECIFICATIONS, 380 Volt-3 Phase- 50Hz
Tube Size
inches
(cm)
1
(2.54)
1 1/4
(3.17)
1 1/2
(3.18)
Nominal Capacity
(1)
lbs/day
(Kg/day)
20,000
(9,072)
18,000
(8,165)
16,500
(7,484)
Overall Dimensions (LxWxH)
inches
(meters)
48 x 60 x 129
(1.2x1.5x3.3)
48 x 60 x 129
(1.2x1.5x3.3)
48 x 60 x 129
(1.2x1.5x3.3)
Shipping Weight
lbs
(Kg)
4800
(2177)
4800
(
2177)
4800
(2177)
Operating Weight
lbs
(Kg)
4900
(2222)
4900
(
2222)
4900
(2222)
Refrigerant Charge (R404A)
lbs
(Kg)
500
(238)
500
(238)
500
(
238)
Total FLA Water Cooled
(2)
66.5
66.5
66.5
Total FLA Air Cooled
(2)
75
75
75
Maximum Fuse
WC / AC
150/160
150/160
150/160
Minimum Ampacity
WC / AC
83/97
83/97
83/97
Water Requirements
-makeup
(3)
gpm
(m
3
/ Hr)
3.0
(0.68)
3.0
(0.68)
3.0
(0.68)
-condenser
(4)
gpm
(m
3
/ Hr)
70
(15.9)
70
(15.9)
70
(15.9)
Connection Sizes
-makeup water
FPT
3/4”
3/4”
3/4”
-tank drain
FPT
3/4”
3/4”
3/4”
-condenser water inlet
FPT
2”
2”
2”
-condenser water outlet
MPT
2”
2”
2”
-AC condenser inlet
ODC
2 1/8”
2 1/8”
2 1/8”
-AC condenser outlet
ODC
1 3/8”
1 3/8”
1 3/8”
Compressor -HP/KW/FLA
24 / 17.9 / 62.5
24 / 17.9 / 62.5
24 / 17.9 / 62.5
Water Pump -HP/KW/FLA
2 / 1.5 / 3.6
2 / 1.5 / 3.6
2 / 1.5 / 3.6
Cutter Motor -HP/KW/FLA
0.5 / 0.4 / 1.1
0.5 / 0.4 / 1.1
0.5 / 0.4 / 1.1
THR
Btu/hr
(kW)
275,000
(73.3)
275,000
(73.3)
275,000
(73.3)
Marley Cooling Tower
(5)
4822
4822
4822
-dim. (LxWxH)
ft
(meters)
4 x 5 x 6.5
(1.2x1.5x2.0)
4 x 5 x 6.5
(1.2x1.5x2.0)
4 x 5 x 6.5
(1.2x1.5x2.0)
-shipping weight
lbs
(Kg)
650
(295)
650
(295)
650
(295)
-operating weight
lbs
(Kg)
1260
(
571)
1260
(
571)
1260
(
571)
-fan (HP/KW/FLA)
1 / 0.8 / 3.6
1 / 0.8 / 3.6
1 / 0.8 / 3.6
Tower Pump
-flow
gpm
(m
3
/Hr)
78
(17.7)
78
(17.7)
78
(17.7)
-TDH
minimum
ft
(m)
80
(24.4)
80
(24.4)
80
(24.4)
-HP/KW/FLA
3 /2.2 / 9.6
3 /2.2 / 9.6
3 /2.2 / 9.6
-connections (inlet x outlet)
FPT
4” x 3”
4” x 3”
4” x 3”
-shipping weight
lbs
(Kg)
65
(29.5)
65
(29.5)
65
(29.5)
Bohn Air-Cooled Condenser
(6)
BNHS04A029
BNHS04A029
BNHS04A029
- # of Fans / HP
4 / 1.5
4 / 1.5
4 / 1.5
-total KW/FLA
4.5 / 14
4.5 / 14
4.5 / 14
-inlet connection
ODC
2 1/8”
2 1/8”
2 1/8”
-outlet connection
ODC
1 3/8”
1 3/8”
1 3/8”
-shipping weight
lbs
(Kg)
1520
(690)
1520
(690)
1520
(
690)
-operating weight
lbs
(Kg)
1265
(574)
1265
(574)
1265
(
574)
(1) Nominal capacity is based on 70°F makeup water, 100°F condensing temp, 70°F amb, and 0% blowdown.
(4) Condenser flow rate is for 85°F entering water temperature and 100°F condensing.
(2) FLA for 200 volt models is approximately 2 times that of 380 volt models. Total FLA does not include cooling tower.
(5) Tower sized for 80°F wet bulb temperature.
(3) Makeup water is maximum value and includes 10 gallons per cycle blowdown.
(6) Recommended air-cooled condenser is based on 15°F TD.
Vogt reserves the right to change designs and specifications without notice.
Table 11-2
Summary of Contents for P18FXT
Page 4: ...Vogt Tube Ice Machines Installation Service Manual and Parts Catalog 12A4171M08 10TA Model ...
Page 10: ...10TA Service Manual TABLE OF CONTENTS vi BLANK ...
Page 20: ...10TA Service Manual INTRODUCTION 4 14 14 1 10 BLANK ...
Page 40: ...10TA Service Manual INSTALLING YOUR TUBE ICE MACHINE 4 14 14 3 18 BLANK PAGE ...
Page 50: ...10TA Service Manual START UP AND OPERATION 4 14 14 5 6 BLANK ...
Page 60: ...10TA Service Manual ELECTRICAL CONTROLS 4 14 14 6 10 BLANK ...
Page 112: ...10 8 10TA Service Manual OPTIONS AND ACCESSORIES BLANK ...
Page 120: ...10TA Service Manual TABLES CHARTS 7 2 14 11 8 BLANK ...