![Vogt P18FXT Service Manual Download Page 103](http://html.mh-extra.com/html/vogt/p18fxt/p18fxt_service-manual_1044456103.webp)
10TA Service Manual
SERVICE OPERATIONS
4/28/14
9-23
Defrost Pressure Switch –DPS (R404A Machines only).
The DPS is used to regulate the pressure
in the freezer during the harvest cycle. This pressure switch is wired in series with the D-valve
(thaw gas valve), which opens and closes during the harvest cycle to maintain 90 to 95 psig in the
evaporator.
Defrost Pressure Switch (DPS)
FIGURE 9-19
Pressure Relief Valves.
Pressure relief valves are installed on the freezer, receiver and the water
cooled condenser. These valves are designed to vent in emergency conditions. This ensures vessel
internal pressure does not exceed maximum allowable pressures.
CUT IN (CLOSE) ADJUSTING SCREW
SET AT 90 PSIG
(CW LOWERS SETTING)
Vogt Part #:
CUT OUT (OPEN) ADJUSTING SCREW
SET AT 95 PSIG
(CW RAISES SETTING)
CE Approved machine
Vogt Part #:
PRESSURE RELIEF VALVES MUST BE REPLACED
AFTER 5 YEARS OF SERVICE.
BEFORE REPLACING RELIEF VALVE, REVIEW REQUIREMENTS PER
CURRENT LOCAL AND NATIONAL CODE.
VALVE REPLACEMENT SHOULD BE MADE BY PROPERLY TRAINED
PERSONNEL ONLY.
NOTE: IF REFIEF VALVE DISCHARGES, VALVE MUST BE REPLACED BECAUSE
SETTING OR SEAT TIGHTNESS MAY BE ALTERED.
CONTACT VOGT ICE PARTS DEPARTMENT FOR REPLACEMENT VALVES.
PHONE: 502-635-3000
Summary of Contents for P18FXT
Page 4: ...Vogt Tube Ice Machines Installation Service Manual and Parts Catalog 12A4171M08 10TA Model ...
Page 10: ...10TA Service Manual TABLE OF CONTENTS vi BLANK ...
Page 20: ...10TA Service Manual INTRODUCTION 4 14 14 1 10 BLANK ...
Page 40: ...10TA Service Manual INSTALLING YOUR TUBE ICE MACHINE 4 14 14 3 18 BLANK PAGE ...
Page 50: ...10TA Service Manual START UP AND OPERATION 4 14 14 5 6 BLANK ...
Page 60: ...10TA Service Manual ELECTRICAL CONTROLS 4 14 14 6 10 BLANK ...
Page 112: ...10 8 10TA Service Manual OPTIONS AND ACCESSORIES BLANK ...
Page 120: ...10TA Service Manual TABLES CHARTS 7 2 14 11 8 BLANK ...