* All Pictures In This Manual Are For Illustrative Purposes Only. Actual Product May Vary.

© 2021 United States Stove Company, 227 Industrial Park Rd., South Pittsburg, TN 37380      Ph. 800-750-2723

THIS MANUAL IS SUBJECT TO CHANGE WITHOUT NOTICE.

Owner’s Instruction and Operation Manual

U.S. Environmental Protection Agency

Certified to comply with 2020 particulate 

emissions standards.

SAFETY NOTICE: If this heater is not properly installed, a house fire may result. For 
your  safety,  follow  the  installation  instructions.  Never  use  make-shift  compromises 
during  the  installation  of  this  heater.  Contact  local  building  or  fire  officials  about 

permits, restrictions and installation requirements in your area. NEVER OPERATE THIS 
PRODUCT WHILE UNATTENDED.

CAUTION!  Please  read  this  entire  manual  before  you  install  or  use  your  new  room 

heater. Failure to follow instructions may result in property damage, bodily injury, or 

even death. Improper Installation Will Void Your Warranty!

Save These Instructions In A Safe Place For Future Reference.

 CALIFORNIA PROPOSITION 65 WARNING:

This product can expose you to chemicals 

including carbon monoxide, which is known to the 

State of California to cause cancer, birth defects, 

and/or other reproductive harm. For more 

information, go to 

www.P65warnings.ca.gov

853140K-0302K

VG130

R

Report #: F20-570

Certified  to  ASTM  E1509-12  (2017), 

and Certified to ULC-S627-00-REV1

Mobile Home Approved

Model Number:

Summary of Contents for VG130

Page 1: ...or fire officials about permits restrictions and installation requirements in your area NEVER OPERATE THIS PRODUCT WHILE UNATTENDED CAUTION Please read this entire manual before you install or use your new room heater Failure to follow instructions may result in property damage bodily injury or even death Improper Installation Will Void Your Warranty Save These Instructions In A Safe Place For Fut...

Page 2: ... heater meets the 2020 U S Environmental Protection Agency s crib wood emission limits for wood heaters sold after May 15 2020 Under specific EPA test conditions burning wood pellet fuel this heater has been shown to deliver heat at a rate of 8 932 to 25 701 Btu hr This heater achieved a particulate emissions rate of 1 3 g hr when tested to method ASTM E 2779 EPA Method 28R and 64 efficiency For C...

Page 3: ..._________________________________________ If no Date of inspection of existing venting system ___________________________________________________________________ COMMISSIONING Confirm Hearth Pad Installation as per Installation Instructions Confirm proper placement of internal parts Check soundness of door gasket and door seals Confirm clearances to combustibles as per installation instructions in...

Page 4: ...ETECTOR MUST BE INSTALLED IN THE SAME ROOM AS THIS PRODUCT INSTALL A SMOKE DETECTOR ON EACH FLOOR OF YOUR HOME INCASE OF ACCIDENTAL FIRE FROM ANY CAUSE IT CAN PROVIDE TIME FOR ESCAPE THE SMOKE DETECTOR MUST BE INSTALLED AT LEAST 15 FEET 4 57 M FROM THE APPLIANCE IN ORDER TO PREVENT UNDUE TRIGGERING OF THE DETECTOR WHEN RELOADING CAUTION BURNING FUEL CREATES CARBON MONOXIDE AND CAN BE HAZARDOUS TO ...

Page 5: ... WALL ADJACENT WALL H ADJACENT WALL H H ADJACENT WALL H J in mm PARALLEL E Backwall to unit 2 50 F Sidewall to flue 13 330 G Sidewall to top edge of unit 8 203 CORNER H Adjacent wall to unit 8 203 ALCOVE J Alcove depth 36 914 OUTSIDE AIR SUPPLY OPTIONAL UNLESS INSTALLING IN A MOBILE HOME ATTENTION DO NOT VENT UNDER ANY PORCH DECK AWNING OR IN ANY SEMI ENCLOSED OR ROOFED AREA DOING SO MAY RESULT IN...

Page 6: ...EM OTHER THAN THE WAY EXPLAINED IN THIS MANUAL IT WILL NOT FUNCTION PROPERLY MAXIMUM VENTING DISTANCE Installation MUST include at least 3 feet of vertical pipe outside the home This will create some natural draft to reduce the possibility of smoke or odor during appliance shutdown and keep exhaust from causing a nuisance or hazard by exposing people or shrubs to high temperatures The maximum reco...

Page 7: ...erformance and or malfunction The termination must exhaust above the outside air inlet elevation The termination must not be located where it will become plugged by snow or other materials Do not terminate the venting into an existing steel or masonry chimney VENT TERMINATION CLEARANCES A Minimum 4 foot 1 22m clearance below or beside any door or window that opens B Minimum 1 foot 0 3m clearance a...

Page 8: ...tallation you have to be aware of the snowdrift line dead grass and leaves We recommend a 3ft 0 91m minimum vertical rise on the inside or outside of the house The through the wall installation is the least expensive and simplest installation Never terminate the end vent under a deck in an alcove under a window or between two windows We recommend Simpson Dura Vent or Metal Fab kits THROUGH THE ROO...

Page 9: ...ntinues to flow with too little air for long enough the burn pot will fill with too much fuel and the fire will smother out To much air will result in a flame that is overactive or aggressive The flame in this situation is typically very blue at the bottom and resembles a blow torch If this situation continues the fuel in the burn pot will be consumed and the fire will go out Matching the amount o...

Page 10: ...ge setting However this speed can be manually operated by pressing the Draft Fan arrows up or down Draft Fan when pressed the display will show Df A which is automatic Press the arrows again to adjust fan speed When the heater is in the manual mode the optional thermostat will not properly control the unit When adjusting the Draft Fan setting try only 1 setting above or below the heat setting It i...

Page 11: ... the stove cycle between the preselected desired heat range setting 1 to 5 and the minimum heat range setting of 1 The T Stat will not turn the stove on and off When the desired room temperature has been reached and the T Stat no longer requires heat it will reduce to a minimum heat range setting of 1 The unit will not turn completely off Once the room temperature has dropped and the T Stat requir...

Page 12: ... reduced performance Store your pellets in a dry place DO NOT store the fuel within the installation clearances of the unit or within the space required for refuelling and ash removal Doing so could result in a house fire Do not over fire or use volatile fuels or combustibles doing so may cause a personal and property damage hazards THIS STOVE IS APPROVED FOR BURNING PELLETIZED WOOD FUEL ONLY Fact...

Page 13: ...M SPARKS OR FUMES ENTERING THE ROOM THE DOOR MUST BE CLOSED AND SEALED DURING OPERATION If the door is opened while the stove is in operation it must be closed within 30 seconds or the stove will shut down If the stove shuts down push the On Off button to re start your stove The stove will have to fully shut down and turn off before you will be able to restart the stove ROOM AIR FAN When starting ...

Page 14: ...or more than 30 seconds during operation will cause enough pressure change to activate the air switch shutting the fuel feed off The stove will shut down and show E2 on the two digit display The stove has to fully shut down before restarting INTERIOR CHAMBERS Burn Pot Periodically remove and clean the burn pot and the area inside the burn pot housing In particular it is advisable to clean out the ...

Page 15: ...ofessionally inspected cleaned and if necessary repaired To clean the chimney disconnect the vent from the stove FLY ASH This accumulates in the horizontal portion of an exhaust run Though non combustible it may impede the normal exhaust flow It should therefore be periodically removed ASH REMOVAL DISPOSAL CAUTION ALLOW THE STOVE TO COOL BEFORE PERFORMING ANY MAINTENANCE OR CLEANING ASHES MUST BE ...

Page 16: ...r unforeseen safety hazards PAINTED SURFACES Painted surfaces may be wiped down with a damp cloth If scratches appear or you wish to renew your paint contact your authorized dealer to obtain a can of suitable high temperature paint GLASS We recommend using a high quality glass cleaner Should a buildup of creosote or carbon accumulate you may wish to use 000 steel wool and water to clean the glass ...

Page 17: ...r until the hopper is empty and pellets stop flowing this can be done by pressing the ON button with the viewing door open Vacuum out the hopper Thoroughly clean the burn pot and firebox It may be desirable to spray the inside of the cleaned hopper with an aerosol silicone spray if your stove is in a high humidity area The exhaust system should be thoroughly cleaned MAINTENANCE SCHEDULE Use the fo...

Page 18: ... gaskets Check that all outside connections are clear of any obstructions Check the exhaust system clean as needed Check that the pressure switch connection to the firebox is free of ash or clear of obstructions Auger system is jammed or there is a bridging of the fuel in the hopper preventing fuel from flowing into the auger feed system PROBLEM CAUSE Auto Start Igniter fails to ignite the fuel in...

Page 19: ...e Flashing Off This indicates that the stove is in the Shut Down state waiting for the off button or for a 15 minute period after the stove was turned off or for the stove to cool down or for the door to be closed Flashing dash in Heat Range Display This indicates that the stove is in the normal run mode and is ramping from the current heat range setting to the target heat range setting Once the r...

Page 20: ...20 2021 United States Stove Company 47 46 48 49 PARTS LIST ...

Page 21: ...er 1 26 25495 Drive Motor Bracket 1 27 891169 Heater Hose 2 28 80488 Auger Motor 1 29 83529 Hair Pin 1 30 69763 Exhaust Duct Weldment 1 31 88117 Exhaust Duct Gasket 1 32 80473 Exhaust Blower 1 33 88100 Exhaust Blower Gasket 1 34 80480 Thermistor 1 35 86633 Ignitor Tube Weldment 1 36 80619 Ignitor Cartridge 1 37 88118 Ignitor Flange Gasket 1 38 80472 Distribution Blower 1 39 88106 Distribution Blow...

Page 22: ...t 4 5 ft 6 891053 Door Glass 1 7 25521 Top Glass Retainer 1 8 25520 Bottom Glass Retainer 1 9 25393 Glass Retainer 1 To order parts Call 1 800 750 2723 Ext 5051 or Email to parts usstove com IN ORDER TO MAINTAIN WARRANTY COMPONENTS MUST BE REPLACED USING ORIGINAL VOGELZANG PARTS PURCHASED THROUGH YOUR DEALER OR DIRECTLY FROM VOGELZANG USE OF THIRD PARTY COMPONENTS WILL VOID THE WARRANTY PARTS LIST...

Page 23: ...ms are ordered Before contacting customer service write down the model number and the serial number of this unit That information can be found on the certification label attached to the back of the unit Other information that may be needed would be the part number and part description of the item s in question Part numbers and descriptions can be found in the Repair Parts section of this manual On...

Page 24: ...__ Engineer Name ______________________________________ License No _________________________________________ Company ____________________________________________ Telephone No _______________________________________ Stove Inspected Chimney Swept Items Replaced ______________________________________ Service 02 Date ________________________ Engineer Name ______________________________________ License...

Page 25: ..._______________ Service de 07 Date _______________________ Nom de l ingénieur __________________________________ N de licence _______________________________________ Compagnie _________________________________________ N de téléphone ____________________________________ Poêle Inspecté Cheminée balayée Articles Remplacé __________________________________ Service de 02 Date _______________________ No...

Page 26: ...de rechange les informations contenues dans ce manuel vous aideront à vous assurer que les bons articles sont commandés Avant de contacter le service client notez le numéro de modèle et le numéro de série de cet appareil Cette information se trouve sur l étiquette de certification apposée à l arrière de l appareil D autres informations qui pourraient être nécessaires sont le numéro de pièce et la ...

Page 27: ... 88100 Joint D échappement Blower 1 34 80480 Thermistance 1 35 86633 Ignitor Tube Weldment 1 36 80619 Cartouche Ignitor 1 37 88118 Ignitor Bride Joint 1 38 80472 Souffleur De Distribution 1 39 88106 Répartition Du Ventilateur Joint 1 40 25774 Pressostat Support 1 41 80549 Commutateur De Pression 1 42 89586 Mamelon 1 43 891121 Tuyau De Silicone 3 po 44 83537 Collier De Serrage N 4 1 45 88119 Couvertu...

Page 28: ... 2021 United States Stove Company 17 47 46 48 49 PIÈCES DE RECHANGE 1 3 2 4 5 6 8 7 9 ...

Page 29: ...ortant des gants retirez soigneusement les morceaux de verre détachés du cadre de la porte 4 Remplacez la vitre et le joint en vous assurant que le joint parcourt tout le périmètre du bord du verre 5 Réinstaller le dispositif de retenue et les huit écrous et le joint de corde à l aide de silicone haute température pour faire adhérer le joint à la porte 6 N utilisez jamais de matériaux de substitut...

Page 30: ...nt chaque saison de chauffage Pour nettoyer la cheminée déconnecter l évacuation du poêle CENDRES VOLANTES Elles s accumulent dans la portion horizontale du conduit d évacuation Bien qu elles ne soient pas combustibles elles peuvent gêner le flux normal d évacuation Elles doivent donc être périodiquement éliminées ENLÈVEMENT ET ÉLIMINATION DES CENDRES AVERTISSEMENT LAISSEZ LE POÊLE REFROIDIR AVANT...

Page 31: ...dant le fonctionnement provoque un changement de pression suffisant pour activer l interrupteur pneumatique qui arrête l alimentation en combustible Le poêle s éteint et la mention E2 s affiche sur l écran à deux chiffres Le poêle doit s arrêter complètement avant de pouvoir être redémarré CHAMBRES INTÉRIEURES Pot de combustion Retirez et nettoyez périodiquement le pot de combustion et la zone à l...

Page 32: ... ouverte pendant le fonctionnement du poêle elle doit être refermée dans les 30 secondes sinon le poêle s éteint Si le poêle s éteint appuyez sur l interrupteur ON OFF pour le redémarrer Le poêle doit être complètement arrêté et débranché avant de pouvoir être redémarré AVERTISSEMENT NE FAITES PAS FONCTIONNER VOTRE POÊLE AVEC LA PORTE VUE OUVERTE LA TARIÈRE N ALIMENTERA PAS DE GRANULÉS DANS CES CI...

Page 33: ...mouillés réduiront les performances Rangez vos pellets dans un endroit sec NE stockez PAS le carburant dans les dégagements d installation de l appareil ou dans l espace requis pour faire le plein et enlever les cendres Cela pourrait provoquer un incendie Ne pas trop brûler ou utiliser des combustibles volatiles ou des combustibles cela pourrait causer des dommages aux personnes et à la propriété ...

Page 34: ...sorte que le poêle se programme entre le réglage présélectionné de la plage de chaleur désirée 1 à 5 et le réglage de la plage de chaleur minimale de 1 Le T Stat n allumera ni ne éteindra le poêle Lorsque la température ambiante souhaitée est atteinte et que le T Stat n a plus besoin de chaleur le réglage de la plage de chauffage minimale est défini sur 1 L unité ne s éteindra pas complètement Une...

Page 35: ...onformément au réglage du niveau de chaleur Cependant cette vitesse peut être réglée manuellement en appuyant sur les flèches haut et bas du ventilateur de tirage Draft Fan Lorsque le bouton Draft Fan ventilateur de tirage est appuyé l affichage indiquera Df A qui est automatique Appuyez de nouveau sur les flèches pour régler la vitesse du ventilateur Quand le système de chauffage est en mode manu...

Page 36: ...tre approvisionné avec trop peu d air pendant une durée suffisante le pot de combustion se remplira avec trop de combustible et le feu s étouffera Trop d air provoquera une flamme hyperactive ou agressive La flamme dans cette situation est généralement très bleue à la base et ressemble à celle d un chalumeau Si cette situation persiste le combustible dans le pot de combustion sera consumé et le fe...

Page 37: ...ige il est recommandé que l installation soit plus grand que 3 pieds 0 91 m pour obtenir au dessus de la ligne de congère Cette même installation peut être utilisée si votre chauffe eau est en dessous du niveau du sol en ajoutant simplement la section de nettoyage et tuyau vertical intérieur jusqu à ce que le niveau du sol est atteint Avec cette installation vous devez être conscient de la hauteur...

Page 38: ...ème de ventilation doivent être fixés par au moins 3 vis et tous les joints doivent être scellés avec du mastic silicone Hi Temp RTV pour être hermétiques La zone où le tuyau de ventilation pénètre à l extérieur de la maison doit être scellée avec du silicone ou d autres moyens pour maintenir le pare vapeur entre l extérieur et l intérieur de la maison Les surfaces de ventilation peuvent devenir s...

Page 39: ...CES POUR L EVACUATION AVERTISSEMENT INSTALLEZ L ÉVACUATION DES FUMÉES EN RESPECTANT LES DÉGAGEMENTS SPÉCIFIÉS PAR LE FABRICANT D ÉVACUATIONS NE RELIEZ PAS L ÉVACUATION POUR POÊLE À GRANULÉS À UNE ÉVACUATION UTILISÉE POUR UN AUTRE APPAREIL OU UN AUTRE POÊLE N INSTALLEZ PAS DE REGISTRE DE TIRAGE SUR LE SYSTÈME D ÉVACUATION DE CET APPAREIL Les directives d installation ci dessous doivent être respect...

Page 40: ... ce manuel REMARQUE La distance B sur le côté de votre poêle à granulés peut devoir être supérieure au dégagement minimum requis pour un accès approprié au panneau de commande E MUR ARRIÈRE MUR ARRIÈRE PAROI LATÉRALE PAROI LATÉRALE F F G G E MUR ADJACENT MUR ADJACENT MUR ADJACENT MUR ADJACENT H H H H po mm Parallèle E Mur arrière à l unité 2 50 F Paroi latérale au carneau 13 330 G Paroi latérale a...

Page 41: ... VOTRE MAISON EN CAS D INCENDIE ACCIDENTEL DÛ À N IMPORTE QUELLE CAUSE CE DISPOSITIF PEUT LAISSER LE TEMPS DE S ÉCHAPPER LE DÉTECTEUR DE FUMÉE DOIT ÊTRE INSTALLÉ À AU MOINS 15 PIEDS 4 57 M DE L APPAREIL AFIN D ÉVITER QU IL NE SE DÉCLENCHE INUTILEMENT LORS DU RECHARGEMENT DU POÊLE ATTENTION ATTENTION LA COMBUSTION DU COMBUSTIBLE GÉNÈRE DU MONOXYDE DE CARBONE QUI PEUT S AVÉRER DANGEREUX POUR LA SANT...

Page 42: ...non date d inspection du système de ventilation existant _______________________________________________________________________ MISE EN SERVICE Confirmer l installation du tapis de foyer conformément aux instructions d installation Confirmer le bon placement des pièces internes Vérifier la solidité du joint de porte et des joints de porte Confirmer les dégagements aux combustibles selon les instr...

Page 43: ... limites d émission de bois en vigueur aux États Unis en vertu de l Environmental Protection Agency des États Unis pour les appareils de chauffage au bois vendus après le 15 mai 2020 Dans des conditions de test spécifiques à l EPA l utilisation de pellets de bois pour brûler cet appareil de chauffage a permis de générer de la chaleur à un débit de 8 932 à 25 701 Btu h Ce dispositif de chauffage a ...

Page 44: ...es restrictions et les exigences d installation dans votre région NE JAMAIS UTILISER CE PRODUIT SANS SURVEILLANCE MISE EN GARDE Veuillez lire l intégralité de ce manuel avant d installer ou d utiliser votre nouveau radiateur Le non respect des instructions peut entraîner des dommages matériels des blessures corporelles ou même la mort Une installation incorrecte pourrait annuler votre garantie Con...