Manual Mode Control
The following functions will work only after entering Manual Mode.
Function
Button
Set Show position (all the way up)
Hold HIDDEN for one second, release,
then press and release UP
Set Maintenance position
Hold HIDDEN for one second, release,
then press and release DOWN
Exit Manual Mode
Hold HIDDEN for one second, release,
then press and release STOP
Error Correction
Stop Error blinks
Press and hold STOP for 10 seconds
Override 7 Blinks
Press and hold STOP for 10 seconds,
release, then press and hold HIDDEN for
five seconds, release, press UP. Lift will
raise, release the limit switch and stop.
LED Indicators
RED LED
Same as Lift codes
GREEN LED OFF
In Automatic Mode
Slow Blink
In Manual Mode
Fast Blink
Hidden button pressed for 5 seconds,
waiting for next button push – or-
Fast Blink
Confirmation of Set Show/Maintenance
Intermittent Blinking
Reception of IR signal
Fast Blink
20 times Powered up
Pin Assignments: DB9 Male to DB9 Female
1 Black - UP
2 Red – DOWN
3 Green – STOP
4 Blue - SET
5 Yellow - OVERRIDE
6 White Common
7 Purple - LED
8 Orange – Safety Switch Override
9 Brown +5V