64
8 TECHNICAL SPECIFICATIONS
URANOS 4000 GSM
Power supply voltage U1 (50/60Hz)
3x400Vac ±15%
Zmax (@PCC)
57mΩ *
Slow blow line fuse
25A
Communication bus
DIGITAL
MMA maximum input power (kVA)
16.9 kVA
MMA maximum input power (kW)
16.1 kW
TIG maximum input power (kVA)
12.6 kVA
TIG maximum input power (kW)
12.1 kW
MIG/MAG maximum input power (kVA)
16.1 kVA
MIG/MAG maximum input power (kW)
15.3 kW
Power factor PF
0.95
Efficiency (µ)
88%
Cos
0.99
Max. input current I1max
24.4A
Effective current I1eff
18.9A
MMA duty factor (40°C)
(x=40%)
-
(x=50%)
-
(x=60%)
400A
(x=100%)
360A
MMA duty factor (25°C)
(x=80%)
-
(x=100%)
400A
TIG duty factor (40°C)
(x=50%)
-
(x=60%)
400A
(x=100%)
360A
TIG duty factor (25°C)
(x=80%)
-
(x=100%)
400A
MIG/MAG duty factor (40°C)
(x=40%)
-
(x=50%)
-
(x=60%)
400A
(x=100%)
360A
MIG/MAG duty factor (25°C)
(x=80%)
-
(x=100%)
400A
Adjustment range I2
3-400A
Open circuit voltage Uo
73Vdc
Peak voltage Vp
10.1kV
IP Protection rating
IP23S
Insulation class
H
Dimensions (lxdxh)
690x290x510 mm
Weight
36.5 kg.
Manufacturing Standards
EN 60974-1/EN 60974-3
EN 60974-10
Power supply cable
4x4 mm2
Length of power supply cable
5 m
*
This equipment complies with EN/IEC 61000-3-11.
*
This equipment complies with EN/IEC 61000-3-12 if the maximum permissible mains impedance at the interface point to the public grid
(point of common coupling, PCC) is smaller than or equal to the Zmax stated value. If it is connected to a public low voltage system, it is
the responsibility of the installer or user of the equipment to ensure, by consultation with the distribution network operator if necessary, that the
equipment may be connected.