- Access the panel functionalities temporarily (5 minutes) by
rotating the encoder and entering the correct password.
Confirm the change made by pressing button/encoder.
- Unlock the control panel definitively by entering set-up (fol-
low the instructions given above) and bring back parameter
551 to “off”.
Confirm the changes made by pressing button (4)
.
Confirm the change made by pressing the encoder.
3.11 External controls management
Allows the setting of the welding parameters management
method by the external devices (RC, torch…).
Enter set-up by pressing the encoder key for at least 5 seconds.
Select the required parameter (602).
Enter the “External controls management” screen by pressing
the encoder button.
Select the required RC remote control output (CH1, CH2, CH3,
CH4) by pressing button (1).
Select the required parameter (Min-Max-parameter) by pressing
the encoder button.
Adjust the required parameter (Min-Max-parameter) by rotating
the encoder.
Save and exit the current screen by pressing button (4)
.
Cancel the operation by pressing button (3)
.
3.12 Guard limits
Allows the welding process to be controlled by setting warning
limits
and guard limits
for the
main measurable parameters :
Welding current
Welding voltage
Gas flow
Automation movement
Current Consumption (motor 1)
Current Consumption (motor 2)
Coolant flow
Wire speed
Coolant temperature
Enter set-up by pressing the encoder button for at least 5 sec-
onds.
Select the required parameter (801).
Enter the “Guard limits” screen by pressing the encoder button.
Select the required parameter by pressing button (1)
.
Select the method of setting the guard limits by pressing button
(2)
.
Absolute value
%
Percentage value