R750EU5 - IE3 - TE4 - IE4 - ISE4
English
38
Ed.8 / 0-202
GB
RoUTINE mAINTENANCE (AFTER RUNNING-IN)
Frequency
()
Component
Type of inter-
vention
Intervention
procedures
Reference
Every 0
hours
Engine oil (2)
Level control
Top up, if nec-
essary
See “Engine oil
level control”
Coolant (4)
Level control
Top up, if nec-
essary
See “Engine
coolant level
check”
Air filter
Check it is
clean
Clean with low
pressure com-
pressed air.
Check the clog-
ging indicator
that is installed
on the filter body
Clean the filter
or, if necessary,
replace it with a
new one.
See “Cleaning
and replacement
of the air filter”
Coolant fluid
radiator
Check it is
clean
Clean with a
soft brush
Every 300
hours (6)
Engine oil (2)
(6)
Replace
See “Engine oil
change”
Oil filter
Replace the
cartridge
See “Oil filter
cartridge re-
placement”
Air filter
Replace the
main cartridge
See “Cleaning
and replacement
of the air filter”
Check if the
safety cartridge
is clean
Clean with low
pressure com-
pressed air.
See “Cleaning
and replacement
of the air filter”
Fuel filter
Replace
See “Fuel filter
replacement.”
Air intake circuit
and intercooler
pipe
Check it is
clean
Check of pipe
sealing
Dust discharge
circuit
Check it is
clean
Oil separation
circuit
Check of pipe
sealing
Vacuum circuit
Check of pipe
sealing
For each maintenance operation, fill in the
“Periodic maintenance operation record sheet” provided, so as to keep a trace of
the operations performed and therefore establish the most suitable methods for
future operations.
Tech Library http://engine.od.ua