background image

UFL-420/440 water FiLtration system

15

P/N 1010873 Rev. G 03/12

A.J. Antunes & Co.

trOUblesHOOtInG

problem

possible cause

corrective action

Unit does not have power.

The power cord is not correctly 

plugged in.

Plug power cord in correctly.

The Control Display is blank.

The power cord is not correctly 

plugged in.

Plug power cord in correctly.

Control Board is inoperable.

Contact your maintenance person or 

Authorized Service agency.

Transformer is inoperable.

No water comes out of the fil-

ter system

Inlet Valve closed

open the Inlet Valve

Inlet Strainer is plugged

Clean/replace Inlet Strainer

End of the capillaries plugged

Clean/replace Filter Cartridge

Low water flow/pressure out 

of system

See above.

See above.

The system may be in a flush cycle.

Wait for the flush cycle to end.

Flushing program not set correctly 

for water conditions.

Decrease the flush interval and increase 

the flush duration (refer to the operation 

section of this manual).

Drain Valve is stuck open.

Replace/rebuild the Drain Valve.

The inlet water pressure is too low.

Boost the inlet water pressure/replace 

pipes.

Water tastes bad.

Storage/shipping solution not com-

pletely flushed out of system.

Flush system for a longer period of time.

Biological growth in pipes.

Sanitize plumbing.

Water conditions changed.

Consider installing taste and odor filtration.

Broken capillary in Filter Cartridge.

Replace Filter Cartridge.

Flush runs continuously.

Drain Valve stuck open.

Replace/rebuild the Drain Valve.

Controller sending continuous signal 

to valve.

Replace the controller.

Flush runs too long.

Program duration set too long.

Re-program the unit to flush for a shorter 

duration of time.

Flush occurs at time of high 

water usage.

The Flush Interval is set to interfere 

with water use.

Change Flush Interval/reprogram time.  

Unplug unit and plug in at a time of lower 

water usage.

Water splashes at drain dur-

ing flush.

Drain line not positioned properly.

Reposition the end of the drain line.

Water leaks at the ends of the 

Filter Cartridge after changing 

cartridges.

Cartridge end connections are not 

tight enough.

Tighten with wrench if necessary.

o-rings not lubricated.

Lubricate o-rings with food-grade lubricant.

o-rings are split, cut, or twisted

Replace o-rings.

Water leaks from Permeate 

port.

Permeate port is not tight enough

Tighten, with wrench if necessary.

o-ring not lubricated.

Lubricate o-ring with food-grade lubricant.

o-ring split, cut, or twisted.

Replace o-ring.

Water leaks from system fit-

ting or connection.

Fitting broken or loose.

Retighten or replace the fitting.

Not enough pipe thread sealant 

used.

Redo the fitting with the proper amount of 

sealant.

Summary of Contents for UFL-420 series

Page 1: ...rs 9700464 9700466 9700469 9700474 9700476 9700479 System Tested and Certified by NSF International and WQA against NSF ANSI Standard 42 and 53 for the reduction of Standard No 42 Aesthetic Effects No...

Page 2: ...If the unit arrives damaged contact the carrier imme diately and file a damage claim with them Save all packing materials when filing a claim Freight damage claims are the responsibility of the purcha...

Page 3: ...ed States at 1 800 253 2991 Fill in the information in the next column and have it handy when calling for assistance The serial number is on the specification plate located on the unit Purchased From...

Page 4: ...Operating Weight w water lbs Min Clearance for Cartridge Change above or below unit inches 11 5 in 6 in 47 in 42 lbs 38 in Figure 1 Dimensions Electrical Cord Plug Configurations 120 VAC P N 0700665 2...

Page 5: ...ation system 5 P N 1010873 Rev G 03 12 A J Antunes Co Drain Specifications continued Components LED Display Program Button Power Transformer Filter Housing Figure 2 Components Permeate Inlet Flow Cont...

Page 6: ...es listed below The concentration of the indicated sub stances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system as s...

Page 7: ...r Figure 3 The unit MUST be operated with the appropriate Flow Regulator Assembly UFL 420 Units Use a GREEN and WHITE Flow Regulator Assembly 5 gallons per minute UFL 440 Units Use a BLACK and WHITE F...

Page 8: ...for draining and sanitizing the system and downstream plumbing The system should only be connected to the cold water line To ensure that the highest quality water is produced from the system the plum...

Page 9: ...water valve and allow water to enter the system 4 Press and hold the Program button After 6 7 seconds the drain valve will open and F1 will appear on the display 5 Continue holding the Program button...

Page 10: ...am to the filter sys tem 3 Close the inlet water valve and allow the system to depressurize 4 Place a bucket under the T or cross fitting at the inlet connection to the system Open the inlet drain val...

Page 11: ...y Flush Duration Fd on LED display During the Flush Interval mode water enters the inlet and flows through the filter element before exiting the Permeate outlet as usable product water After a cer tai...

Page 12: ...10 seconds NOTE Fi times are displayed in ten minute inter vals after fifty minutes they are displayed in hours Table A PROGRAM PROGRAM 55 Figure 9 Time Setting Fd Mode 55 Seconds PROGRAM 22 Figure 7...

Page 13: ...ke a change press and hold down start button to scroll through settings release button at desired setting Figure 13 4 After ten seconds if start button is not pressed unit automatically returns to Flu...

Page 14: ...7 Make sure there is enough room below the housing to remove the cartridge 8 Remove the snap ring on the end of the housing Grab the raised lug with your fingers or a pair of pliers and pull towards...

Page 15: ...logical growth in pipes Sanitize plumbing Water conditions changed Consider installing taste and odor filtration Broken capillary in Filter Cartridge Replace Filter Cartridge Flush runs continuously D...

Page 16: ...873 Rev G 03 12 A J Antunes Co Wiring Diagram BLK BLK WHT 14 GA AWM 105 C 22 GA AWM 105 C NOTE ALL WIRES TO BE 16 GA AWM 105 C UNLESS OTHERWISE SPECIFIED WHT TERMINAL BLOCK POWER CORD BLK SOLENOID VAL...

Page 17: ...UFL 420 units For UFL 440 units it is BLACK and rated at 10 GPM WARNING Use only a 5 GPM Flow Regulator with UFL 420 units and a 10 GPM Flow Regulator for UFL 440 units Use of the wrong Flow Regulato...

Page 18: ...6 0503983 Control Housing 1 17 0700665 Power Supply 120 V 5 20P 1 0700666 Power Supply 230 V CEE 7 7 1 0700682 Power Supply 220 V HKH 01 1 China Only 19 4060355 Terminal Block 3 Pole 1 20 306P101 Nut...

Page 19: ...UFL 420 440 water filtration system 19 P N 1010873 Rev G 03 12 A J Antunes Co NOTES...

Page 20: ...warranty does not include overtime charges or work done by unauthorized service agencies or personnel This warranty does not cover normal maintenance calibra tion or regular adjustments as specified i...

Reviews: