UFL-420/440 water FiLtration system
6
P/N 1010873 Rev. G 03/12
A.J. Antunes & Co.
perfOrmance Data sHeet
filter cartridge capacities
Maximum operating Pressure
100 psig (690 kPa)
Minimum operating Pressure
8 psig (55 kPa)
Maximum operating Temperature
104°F (40°c)
Minimum operating Temperature
40°F (4°c)
Maximum Trans Membrane Pressure 45 PSI (3.1 Bar)
pH Range
3-10
MWco
100 kD
system capacities
series
Ufl-420
Ufl-440
Liters per hour
1045
2089
Liters per minute
17
35
Gallons per hour
276
552
Gallons per minute
4.6
9.2
System Tested and Certified by NSF
International against NSF/ANSI
Standard 42 and 53 for the reduction of:
Standard No. 42: Aesthetic Effects
Nominal Particulate Reduction Class I
Standard No. 53: Health Effects
Cyst Reduction
Turbidity Reduction
This system has been tested according to NSF/ANSI
Standard 42 and 53 for reduction of the substances
listed below. The concentration of the indicated sub-
stances in water entering the system was reduced to a
concentration less than or equal to the permissible limit
for water leaving the system, as specified in NSF/ANSI
42 or 53. While testing was performed under standard
laboratory conditions, actual performance may vary.
performance claims for percent reduction
substance
Influent
challenge
concentration
reduction
requirement
minimum
%
reduction
cyst
1
minimum
50,000/L
99.95%
99.95%
Turbidity
11+/1 NTU
≤ 0.5 NTU
97.3%
Particulate Class I
Particles 0.5 to <
1
µ
m
at least 10,000
particles /mL
85%
N/A
1based on the use of microspheres or
Cryptosporium parvum
oocysts
Unpacking
1. Remove the system and all packing materials
from the shipping carton.
2. Remove all packing materials and protective cov-
erings from the system
3. Remove the information packet. To prevent any
delay in obtaining warranty coverage, fill out and
mail the warranty card.
nOte: If any parts are damaged, contact antunes
filtration technologies ImmeDIately at 1-800-253-
2991 or 1-630-784-1000.