![Vixel InSpeed 375 User Manual Download Page 35](http://html1.mh-extra.com/html/vixel/inspeed-375/inspeed-375_user-manual_1041068035.webp)
V
IXEL
I
N
S
PEED
™ SAN S
TORAGE
S
WITCH
M
ODEL
375
C
HAPTER
3 S
WITCH
M
ANAGEMENT
U
SER
’
S
G
UIDE
EMBEDDED
IN
THE
FUTURE
OF
STORAGE
32
To create a custom Smart Setting based on an existing Smart Setting:
1. Select a Smart Setting from the list box that most closely matches the port settings that
the new Smart Setting should have.
2. Click
Clone
.
3. Enter the new Smart Setting name.
A name may consist of up to 28 alphanumeric characters and cannot contain spaces (use
underscores for spaces in names).
4. Click
OK
.
The new Smart Setting is added to the list box.
5. Click
Submit
to save the new Smart Setting.
To modify a custom Smart Setting:
1. Ensure the custom Smart Setting is not currently assigned to a port before making any
changes.
2. Select the custom Smart Setting in the list box.
3. Select the new settings.
4. Click
Submit
to save the new settings.
To rename a custom Smart Setting:
1. Select the desired Smart Setting from the list box.
2. Click
Rename
.
3. Enter the new Smart Setting name.
A name may consist of up to 28 alphanumeric characters and cannot contain spaces (use
underscores for spaces in names).
4. Click
OK
.
The new Smart Setting name appears in the list box.
5. Click
Submit
to save the change.
To delete a custom Smart Setting:
1. Ensure the custom Smart Setting is not selected or currently in use.
2. Select the custom Smart Setting in the list box.
3. Click
Delete
.
4. Click
Submit
to save the settings.
Smart Setting Assignments
The Smart Settings are based on several port settings grouped into the following categories:
•
Port Information
•
Pre-Insertion Testing
•
Change Notifications
•
Port Recovery
•
Diagnostics
These settings can be adjusted on custom Smart Settings; however, these settings are fixed on
the default Smart Settings.