endtime
hh:mm
24:00
6/6
End time of the weekly schedule.
(00:00~24:00 indicates schedule
always on)
prefix
string[16]
<blank>
6/6
Indicate the prefix of the
filename.
cyclesize
200~ 100
6/6
The maximum size for cycle
recording in Kbytes when
choosing to limit recording size.
reserveamount 0~ 100
6/6
The reserved amount in Mbytes
when choosing cyclic recording
mechanism.
dest cf,
0~4
cf
6/6
The destination to store the
recorded data.
“cf” means local storage (CF or SD
card).
“0” means the index of the
network storage.
cffolder
string[128]
NULL
6/6
Folder name.
maxsize
100~2000
100
6/6
Unit: Mega bytes.
When this condition is reached,
recording file is truncated.
maxduration
60~3600
60
6/6
Uuit: Second
When this condition is reached,
recording file is truncated.
adaptive_enable
0,1
0
6/6
Indicate whether the adaptive
recording is enabled
adaptive_preevent
0~9
1
6/6
Indicate when is the adaptive
recording started before the event
trigger point (seconds)
adaptive_postevent
0~10
1
6/6
Indicate when is the adaptive
recording stopped after the event
trigger point (seconds)