VIVOTEK
254 - User's Manual
mdwin
0,<positive integer>
6/6
Indicate the source window id of motion
detection.
This field is required when trigger condition is
“md”.
One bit represents one window.
The LSB indicates the 1
st
window.
For example, to detect the 1
st
and 3
rd
windows,
set mdwin as 5.
mdwin0
0,<positive integer>
6/6
Similar to mdwin. The parameter takes effect
when profile 1 of motion detection is enabled.
vi
0,<positive integer>
6/6
Indicate the source id of vi trigger.
This field is required when trigger condition is
“vi”.
One bit represents one digital input. The LSB
indicates VI 0.
vadp
<product dependent>
0,<positive integer>
6/6
Indicate the source id of vadp event notification.
Each bit corresponds to one vadp source, and
the LSB indicates source id 0.
For example, to detect event from any one of
source id 0, 1 and 3, set vadp to 11.
* Only available when vadp is listed in
"capability_supporttriggertypes"
valevel
0,1
6/6
Select audio detection event.
0: not select
1: select
valevel0
0,1
6/6
Select audio detection profile event.
0: not select
1: select
inter
1~999
6/6
Interval of snapshots in minutes.
This field is used when trigger condition is “seq”.