VIVOTEK
310 - User's Manual
devicecontrol
<boolean>
0/7
Indicate whether to support the peripheral
device control.
* We support this parameter when the version
number (httpversion) is equal or greater than
0305c.
7.28 Customized event script
Group:
event_customtaskfile_i
<0~2>
PARAMETER
VALUE
SECURITY
(get/set)
DESCRIPTION
name
string[40]
6/6
Custom script identification of this entry.
date
string[4~20]
6/6
Date of custom script.
time
string[4~20]
6/6
Time of custom script.
7.29 Event setting
Group:
event_i
<0~(n-1)> n denotes the value of "capability_nevent"
(capability_nevent > 0)
PARAMETER
VALUE
SECURITY
(get/set)
DESCRIPTION
name
string[40]
6/6
Identification of this entry.
enable
0, 1
6/6
Enable or disable this event.
priority
0, 1, 2
6/6
Indicate the priority of this event:
“0”= low priority
“1”= normal priority
“2”= high priority
delay
1~999
6/6
Delay in seconds before detecting the next
event.