VIVOTEK
User's Manual - 211
7.9Time Shift settings
Group:
timeshift
for n channel products and m stream
n denotes the value of "capability_nvideoin", m denotes the value of "capability_nmediastream"
(capability_timeshift > 0)
NAME
VALUE
SECURITY
(get/set)
DESCRIPTION
enable
<boolean>
4/4
Enable time shift streaming.
* We replace this parameter with "
timeshift_c<0~(n-1)>_enable"
when the version number (httpversion) is
equal or greater than 0311c.
c<0~(n-1)>_enable
<boolean>
4/4
Enable time shift streaming.
* We support this parameter when the
version number (httpversion) is equal or
greater than 0311c.
c<0~(n-1)>_s<0~(m-1)
>_allow
<boolean>
4/4
Enable time shift streaming for specific
stream.
7.10 IR cut control
Group:
ircutcontrol
(capability_daynight_c<0~(n-1)>_support > 0)
n denotes the value of "capability_nvideoin"
NAME
VALUE
SECURITY
(get/set)
DESCRIPTION
mode
<Not recommended to use
this>
auto,
day,
night,
di,
schedule…etc
* Available values
are listed in
"capability_daynight
_c<0~(n-1)>_mod
e"
<product
dependent>
6/6
Set IR cut control mode
* We replace this parameter with
"ircutcontrol_c0_mode" when the version
number (httpversion) is equal or greater
than 0311c.
sir
<boolean>
6/6
Enable/disable Smart IR