VIVOTEK
User's Manual - 181
patrolseq
string[120]
<blank>
1/4
The patrol sequence of ePTZ. All the
patrol position indexes will be
separated by ","
patroldwelling
string[160] <blank> 1/4
The dwelling time (unit: second) of
each patrol point, separated by “,”.
preset_i<0~19>_name string[40]
<blank>
1/7
Name of ePTZ preset.
(It should be set by ePreset.cgi rather
than by setparam.cgi.)
preset_i<0~19>_pos
<coordinate> <blank>
1/7
Left-top corner coordinate of the
preset.
(It should be set by ePreset.cgi rather
than by setparam.cgi.)
preset_i<0~19>_size
<window size> <blank>
1/7
Width and height of the preset.
(It should be set by ePreset.cgi rather
than by setparam.cgi.)
7.35 Focus Window setting
Group:
focuswindow_c<0~(n-1)>
for n channel product.
PARAMETER
VALUE
Default
SECURITY
(get/set)
DESCRIPTION
win_i0_enable
<boolean>
0
4/4
Enable or disable the window.
win_i0_home
(0~2368, 0~1776)
(1028,710) 4/4
Left-top corner coordinate of the
window.
win_i0_size
(192~2560, 144~1920) (498x406) 4/4
Width and height of the window.