7.3 digital input behavior define
Group:
di_i<0~(ndi-1)>
(capability.ndi > 0)
NAME
VALUE
SECURITY
(get/set)
DESCRIPTION
normalstate high,
low
1/1
Indicates open circuit or closed circuit
(inactive status)
7.4 digital output behavior define
Group:
do_i<0~(ndo-1)>
(capability.ndo > 0)
NAME
VALUE
SECURITY
(get/set)
DESCRIPTION
normalstate open,
grounded
1/1
Indicate open circuit or closed circuit
(inactive status)
7.5 security
Group: security
NAME
VALUE
SECURITY
(get/set)
DESCRIPTION
privilege_do
<product dependent>
view, operator,
admin
6/6
Indicate which privileges and above
can control digital output
(capability.ndo > 0)
privilege_camctrl
<product dependent>
view, operator,
admin
6/6
Indicate which privileges and above
can control PTZ
(capability.ptzenabled > 0 or
capability.eptz > 0)
user_i0_name
string[64]
6/7
User name of root
user_i<1~20>_name string[64]
6/7
User name
user_i0_pass
password[64] 6/6
Root password
user_i<1~20>_pass password[64] 7/6
User password
user_i0_privilege viewer,
operator,
admin
6/7
Root privilege
user_i<1~20>_ privilege
viewer,
operator,
admin
6/6