Compact Scaler Switcher (with PoC)
able to enter in Auto-switching mode.
Operation Examples
:
Connect INPUT 2, INPUT 4, and INPUT 5 ports with source devices, select INPUT
4 to outputs.
Press and hold for the front key
SOURCE/AUTO
for
7 seconds or more
to enter in
auto-switching mode.
No signal removing or new input, VL120000 just works in auto-switching mode,
and take no action (Output from INPUT 4)
Connect INPUT 3 with a source device, and then it will choose INPUT 3 to output.
Remove the signal of INPUT 3, VL120000 will detect from INPUT 1 to INPUT 5.
And when it detects that input 2 is available, it will choose INPUT 2 to output.
Cut off the power of VL120000, then reboot. As VL120000 is in auto-switching
mode, it will choose INPUT 2 to output.
4.1.3 Volume Adjusting
Not in OSD menu, press VOL – to decrease line volume, VOL + to increase.
Not in OSD menu, press MIC – to decrease MIC volume, MIC + to increase.
4.1.4 Used in OSD Menu
Press
MENU
button to enter in OSD menu, and use
UP
,
DWON
,
LEFT
,
RIGHT
button
to navigate, press
ENTER
button to confirm selection.
MENU
button also can be used
to exit present menu level by level until exit the OSD menu.
4.1.5 Software updating:
VL120000 supports software updating via USB flash disk.
Procedures:
1)
Copy the file “
MERGE_51T.bin
” to the root directory of a USB flash disk. (Make
sure the file is copied to the root directory for normal use. The “
MERGE_51T.bin
”
file is provided/ authorized by
VivoLink.
2)
Plug the USB flash disk to the VL120000 USB port on its front panel.
3)
Press the button “MENU” for
7 seconds or more
to update the software
automatically.
Or press this button for
1 second
to open the OSD menu “Option”
Select
“Software Update” to enter in update procedure.
Or send command
50689%
to update software.